Ir al contenido
Georgia Commons
Menú

Acworth · Ordenanza de zonificación

Appendix B - ZONING ORDINANCE / 73-8 - SITE DEVELOPMENT

73-8.4. Fire Safety Requirements.

Sobre este texto

  • As published by Municode, current through 2026-02-09
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. Accessibility for fire equipment on hard surfaced sub-base (subgrade plus an asphalt first layer or bound crushed stone) shall be maintained through all stages of construction from the time framing begins.

B. Minimum width of private access driveways within a development, excluding parking, shall be 20 feet, and the minimum turning radius shall be 35 feet.

C. Fire hydrants and water service shall be installed to within 300 feet of units under construction before proceeding with framing.

73-8.5 Dumpsters.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:acworth/zoning/73-8.4@2026-02-09-26f7d25efc

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Acworth Zoning Ordinance, 73-8.4. Fire Safety Requirements | Georgia Commons