Bishop · Zoning Ordinance
Article VI - GENERAL PROVISIONS
Section 607. Visitability Requirements for Homes in Subdivisions.
About this text
- As posted on the city's website, retrieved 2026-11-14
- Read by OCR from a scanned page: a character, a name, or a number may be misread.
a. Required.
For all subdivisions developed with five (5) or more dwelling units, a minimum of twenty
(20) percent of units must meet the following “visitability” requirements.
b. Visitability Requirements
i. The home must have a minimum of one (1) no-step entrance into the home that leads from the driveway or public way to an entrance with a minimum 32-inch (width) clear opening to the home. .
il. The home must have at least one bathroom on the same level as the no-step entrance that has a minimum 32-inch clear doorway and path to fixtures that allows ingress and egress by a wheelchair-bound individual. The wheelchair-bound individual must be able to open and shut the bathroom door.
iii. The bathroom wall must be reinforced for grab-bars wood blocking in place to support grab bars as needed.
iv. All exterior and interior doors shall be three feet in width and doors shall provide a minimum 32-inch clear opening.
yi, When located on the same level as the no-step entrance, hallways and passageways shall be a minimum of 42 inches wide.
Vi. Electrical wall outlets/receptacles shall be a minimum of fifteen (15) inches above finished floor when measure from the finished floor to center of the outlet.
Vil. Wall switches controlling light fixtures and fans shall be a minimum of forty-eight (48) inches above finished floor when measured from finished floor to center of switch.