setback, height, and separation.
A. Self-supporting towers erected in the AG, T, L-I, H-I, or MN zoning district shall be set back a distance equal to one-third ( )
the height of the tower from all adjoining property lines where such lines do not
adjoin a residential zoning district and a distance of twice (x2) the height of the tower from all property lines which adjoin a residential zoning district.
B. Self-supporting towers erected in a nonresidential zoning district, excluding the AG T, L-I, H-I, or MN zoning districts, except where otherwise stated in section 4.31.2.A. of this chapter, shall be set
back a distance equal to the full vertical height of the tower from all adjoining
property lines of a nonresidential zoning district and a distance of twice (x2) the height of the tower from all property
lines which adjoin a residential zoning district.
C. Self-supporting towers erected in a residential zoning district shall be set back a distance equal to the full height of the tower from any nonresidential zoning district and a distance of twice (x2) the height of the tower from all property
lines which adjoin a residential zoning district or any residential structure.
D. Self-supporting towers shall be limited to a height of two hundred (200) feet in a AG, T, H-I, or MN zoning district, one
hundred fifty (150) feet in a L-I or G-C zoning district, and one hundred twenty
(120) feet in a P-D, M-U, P-S, 0-C, or P-I zoning district or any residential zoning district.
E. Self-supporting towers shall be separated a distance equal to one-quarter (�) of a mile. (Excludes such towers erected in
the T, H-I or MN zoning district.)
F. For purposes of determining whether the installation of a self-supporting tower
complies with setback requirements, the dimensions of the entire lot shall control, even though the tower may be located on
leased parcels within such lots.