4.29.2. Self-supporting communication tower

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

setback, height, and separation.

A. Self-supporting towers erected in the AG, T, L-I, H-I, or MN zoning district shall be set back a distance equal to one-third ( )

the height of the tower from all adjoining property lines where such lines do not

adjoin a residential zoning district and a distance of twice (x2) the height of the tower from all property lines which adjoin a residential zoning district.

B. Self-supporting towers erected in a nonresidential zoning district, excluding the AG T, L-I, H-I, or MN zoning districts, except where otherwise stated in section 4.31.2.A. of this chapter, shall be set

back a distance equal to the full vertical height of the tower from all adjoining

property lines of a nonresidential zoning district and a distance of twice (x2) the height of the tower from all property

lines which adjoin a residential zoning district.

C. Self-supporting towers erected in a residential zoning district shall be set back a distance equal to the full height of the tower from any nonresidential zoning district and a distance of twice (x2) the height of the tower from all property

lines which adjoin a residential zoning district or any residential structure.

D. Self-supporting towers shall be limited to a height of two hundred (200) feet in a AG, T, H-I, or MN zoning district, one

hundred fifty (150) feet in a L-I or G-C zoning district, and one hundred twenty

(120) feet in a P-D, M-U, P-S, 0-C, or P-I zoning district or any residential zoning district.

E. Self-supporting towers shall be separated a distance equal to one-quarter (�) of a mile. (Excludes such towers erected in

the T, H-I or MN zoning district.)

F. For purposes of determining whether the installation of a self-supporting tower

complies with setback requirements, the dimensions of the entire lot shall control, even though the tower may be located on

leased parcels within such lots.