Columbus · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Chapter 7 - PROJECT DESIGN STANDARDS / Article 12 - STORM DRAINAGE
Section 7.12.12. Driveway Culverts.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Culvert Required. Driveway pipe shall be sized for the 25-year storm event.
B. Pipe Materials. Driveway culverts may be PVC, Reinforced Concrete Pipe or High Density Polyethylene (smooth lined type "S").
C. Inlets and Outlets. The inlet and outlet end of all driveway culverts shall have either flared-end sections or concrete headwalls that meet the standards of Georgia DOT.