A. Culverts. At least two feet between the bottom of the base or sub-base, if used, and the exterior crown of the culvert (top of pipe) is required under the roadway.
B. Pipes in Easements. Pipes included in easements shall have a minimum cover of one foot or at the manufacturers' recommendations.
C. Underground Utilities. A minimum of six inches of cover shall be provided between underground utilities and exterior crown of culverts.
D. Trench Construction. Trench construction for storm drainage pipe shall be in accordance with