Cusseta-Chattahoochee County unified government · Zoning Ordinance
Appendix C - ROADWAY AND SUBDIVISION SPECIFICATIONS / 23 - Cement.
23.01. Portland cement.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Portland cement shall
meet the requirements of AASHTO: M 85 and, in addition, cement which is to be used in Portland cement concrete shall meet the low alkali and the false set requirements of that specification. Cement which has been damaged, or which is partially set, lumpy, or caked shall not be used.
A. Types. Type I or Type II Portland cement shall be used for all Portland cement concrete, except high early strength concrete. If high early strength concrete is used, Type I or Type III Portland cement will be permitted.
B. Blends. Different brands of cement, different types of cement, or the same grade of cement, but from different mills, shall not
be mixed or placed in the same storage bin.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.