Nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial waste and storm water shall conform to the requirements of AASHTO: M86 with the following modifications and additions:

A. Same as above.

B. Same as above.

C. Same as above.

NONREINFORCED PIPE

Internal Diameter In.

Minimum Thickness of Wall, in. (1) Minimum Strength lb/linear ft.

Three-Edge Bearing 12 1 1800 15 11 /4 2000 18 11 /2 2200 21 13 /4 2400 24 21 /8 2600 NOTE 1: Where tongue-and-groove pipe is furnished, it shall have a minimum wall thickness of 13 /4 in. except that the above minimum thickness applies if the groove end is modified to give a groove thickness equal to three-fourths of the thickness of the wall of the pipe. This measurement shall be taken one-quarter in. from the outer end of the groove.

G. The ends of nonreinforced pipe shall be so formed that when the pipe are laid together and joined they will make a conduit with a smooth and regular interior surface.

25.03 Concrete underdrain pipe. Unless otherwise restricted on the plans, concrete underdrain pipe may be extrastrength porous concrete conforming to the requirements of AASHTO: M 176, or standard perforated nonreinforced concrete

underdrain pipe conforming to the requirements of AASHTO: M 86, Table 1, both with the requirements of AASHTO: M 86, Table, 1, Class 1.

Sec. 26. Steel pipe.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:cusseta-chattahoochee/zoning/25.02@2026-11-11-a54dbea913

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Cusseta-Chattahoochee County unified government Zoning Ordinance, 25.02. Nonreinforced concrete pipe | Georgia Commons