A. Posts. Posts shall be a minimum of five feet long and either wood or steel posts may be used. Wood posts shall be at least three inches in diameter, or nom. two × four and straight enough to provide a fence without noticeable misalignment.

Steel posts shall have a minimum weight of 1.3 pounds per foot, and have projections for fastening wire to the fence.

B. Woven wire fence. Wire fence fabric shall be at least 32 inches high, and shall have at least six horizontal wires. Vertical wires shall be spaced 12 inches apart. The top and bottom wires shall be at least ten gage. All other wires shall be at least 121 /2 gage.

C. [Filter fabric.] Filter fabric shall be composed of strong rot-proof synthetic fibers formed into a fabric of either the woven or

nonwoven type. Either type of fabric shall be free of any treatment or coating which might significantly alter its physical properties after installation. The fabric shall contain stabilizer and/or inhibitors to make

the filaments resistant to deterioration resulting from exposure to sunlight or heat. The fabric shall be a pervious sheet of synthetic fibers oriented into a stable network so that the fibers retain their relative position with respect to each other.

The fabric shall meet the following physical requirements:

_________________________________________________________________________________________________ Physical Requirements

Physical Property Test Method Requirements Tensile Strength ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute 100 lbs min.

Grab Elongation ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute 30% +- 10% EOS (Equivalent Opening Size) Corps of Engineers Guide Specification CW 022115, November, 1977 100 Sieve min 40 Sieve max Ultraviolet Stability ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute.

Test to be made after 180 days direct exposure to sunlight on a horizontal plane.

80 lbs min Bursting Strength ASTM D751 Diaphragm Bursting Tester 175 psi min _________________________________________________________________________________________________ The contractor shall furnish certified test

reports with each shipment of material attesting that the fabric meets the requirements of this specification.

D. Wire staples for wooden posts. Wire staples shall be a No. 9 gage and shall be at least 11

/2 inches long.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:cusseta-chattahoochee/zoning/appendix-c-1.02@2026-11-11-26bab96e0b

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Cusseta-Chattahoochee County unified government Zoning Ordinance, 1.02 (Appendix C). Materials | Georgia Commons