Sec. 32-333. Measurements, tests and analyses, and sample collection.

About this text

  • As published by Municode, current through 2020-02-10
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Any measurements, tests, analyses, sample types, sample containers and/or holding times to which reference is made in this chapter shall

be determined in accordance with procedures and specifications as set forth in 40 CFR 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 CFR 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance

with procedures approved by EPA.

(b) Analyses shall be determined at the control manhole, or upon a suitable sample taken at the control manhole. If no control manhole is

available on the building sewer, the control manhole shall be considered the nearest downstream manhole to which the building sewer is directly connected. When the director deems it

necessary, the owner of any property served by a building sewer carrying industrial wastes shall install a suitable control manhole on the building sewer to facilitate observation and sampling of wastes. This manhole, when required, shall be accessible, safely located, and constructed at the owner's expense in accordance with county specifications.

(c) Except as indicated in subsection (d) of this section, the user must collect wastewater samples using flow proportional composite sampling techniques. In the event flow proportional sampling is infeasible, the director may authorize the use of time proportional sampling or a minimum of four grab samples where the user

demonstrates that this will provide a representative sample of the effluent being discharged.

In addition, grab samples may be required to show compliance with instantaneous discharge limits.

(d) Samples for oil and grease, temperature, Ph, cyanide, phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques.

History

The history line the source prints at the end of the section.

(Comp. Ords. 2008, ch. 25, art. III, div. 5, § 11)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:dunwoody/zoning/32-333@2020-02-10-34a065c57f

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Dunwoody Zoning Ordinance, Sec. 32-333. Measurements, tests and analyses, and sample collection | Georgia Commons