Sec. 75-595. Culverts.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Pipe size shall be determined by standard engineering practices, but in no case be sized to handle less than a 25-year post-developed storm event. All cross drainpipes for driveways shall be either fully bituminous coated, concrete, or corrugated high-density polyethylene pipe with the appropriate bedding, inlet/outlet protection, and headwalls/flared-end sections. Installations shall be in accordance with DOT standards. Supporting calculations/hydrology study shall be submitted for all flows for which a culvert is to handle. Pipe gauge (thickness) shall
be as determined by the height of the fill. Minimum cover pipes shall be 12 inches.