Pipe size shall be determined by standard engineering practices, but in no case be sized to handle less than a 25-year post-developed storm event. All cross drainpipes for driveways shall be either fully bituminous coated, concrete, or corrugated high-density polyethylene pipe with the appropriate bedding, inlet/outlet protection, and headwalls/flared-end sections. Installations shall be in accordance with DOT standards. Supporting calculations/hydrology study shall be submitted for all flows for which a culvert is to handle. Pipe gauge (thickness) shall
be as determined by the height of the fill. Minimum cover pipes shall be 12 inches.