(a) Described. Areas of Special Flood Hazard may include designated "AO" shallow flooding areas. These areas have base flood depths of one (1) to three (3) feet above ground, with no clearly defined channel.
(b) Elevation of Lowest Floor. All substantial improvements of residential and non-residential structures shall have the lowest floor, including basement, elevated to no lower than one (1) foot above the flood
depth number in feet specified on the Flood Insurance Rate Map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three (3) feet above the highest adjacent grade.
(c) Openings Below Elevated Structures. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Section 32.32(a), (b), and
(c) of this Article.
(d) Drainage. Drainage paths shall be provided to guide floodwater around and away from any proposed structure.
History
(Ord. No. 578, § 1, 8-1-2019)