Glynn County · Zoning Ordinance
Article 5 - TELECOMMUNICATION USES
5.1.7. Requirements for Telecommunications Facilities
About this text
- As posted on the county's website, retrieved 2026-11-23
A. General Requirements for All Telecommunications Facilities This Sec. 5.1.7.A regulates the location and construction of all telecommunications facilities governed by this ordinance. Antennae and towers may be considered either principal or accessory uses. A different existing use or an existing structure on the same lot shall not preclude the installation of an antenna or tower on such lot.
1. Building Codes: Safety Standards. To ensure the structural integrity of towers, the owner of a tower must certify that it is maintained in compliance with building code standards and the applicable standards for towers that are published by the Electronic Industries Association, as amended from time to time. If, upon inspection, the County concludes that a tower fails to comply with such codes and standards or constitutes a danger to persons or property, then upon notice being provided to the owner of the tower by the Board of Commissioners, the owner will have 15 days in which to bring such tower into compliance with such standards. If the owner fails to bring such tower into compliance, the County may remove such tower at the owner’s expense. Any such removal by the County must be in the manner provided in Sec. 5.1.10 (Removal of Facilities).
2. State and Federal Regulatory Compliance.
a. All towers must meet or exceed current standards and regulations of the FAA, the FCC, and any other agency of the state or federal government with the authority to regulate towers and antennae. If such standards and regulations are changed, then the owners and tenants of the towers and antennae governed by this ordinance shall bring such towers and antennae into compliance with any revised standards. Failure to bring towers and antennae into compliance with revised standards and regulations shall constitute grounds for the removal of the tower or antenna at the owner’s expense.
b. Owners of telecommunications must provide evidence that each telecommunications facility meets all federal and state requirements. Evidence of compliance must be submitted to the Planning & Zoning Department every 12 months.
3. Security. All telecommunications facilities must be enclosed by decay-resistant security fencing not less than six feet in height and shall be equipped with an appropriate anti-climbing device.
4. Lighting. No illumination is permitted on telecommunications facilities unless required by the FCC, FAA, or other state or federal agency of competent jurisdiction or unless necessary for air traffic safety. If lighting is required or necessary, the Planning Commission may review the available lighting alternatives and approve the design that would cause the least disturbance to the surrounding uses or views.
5. Location on Signs. Telecommunications facilities may be allowed on any legally permitted permanent sign as long as the other requirements of this ordinance are met.
6. Visual Impact.
a. Telecommunications facilities must either maintain a galvanized steel finish or, subject to any applicable standards of the FAA or other applicable federal or state agency, be painted a neutral color or painted and/or textured to match the existing structure so as to reduce visual obtrusiveness. In the design of telecommunications facilities, the owners must make use of all available camouflaging and concealment techniques, including, but not limited to, installing second arrays on existing utility towers or co-locating on existing towers.
b. If an antenna is installed on a structure other than a tower, the antenna and associated electrical and mechanical equipment must be of a neutral color that is identical to, or closely compatible with, the color of the supporting structure so as to make the antenna and related equipment as visually unobtrusive as possible. Roof-mounted antennae must be made visually unobtrusive by screening to match existing air conditioning units, stairs, elevator towers, or other existing background.
c. Telecommunications facilities mounted on architecturally significant structures or significant architectural details of a building must be covered by appropriate casings, which are manufactured to match existing architectural features found on the building.
d. Where feasible, telecommunications facilities should be placed directly above, below, or incorporated with vertical design elements of the building to help in camouflaging.
e. Any equipment shelter or cabinet that supports telecommunications facilities must be concealed from public view or made compatible with the architecture of the surrounding structures or placed underground. Equipment shelters or cabinets must be screened from public view by using landscaping or materials and colors consistent with the surrounding backdrop. The shelter or cabinet must be regularly maintained.
7. Landscaping
a. Tower facilities must be landscaped with a buffer of plant materials that effectively screens the view of the tower base and buildings from adjacent residential property. The buffer must consist of a landscaped strip at least four feet high and deep outside the perimeter of the base and buildings. The strip must be maintained to ensure the facility is effectively screened from view.
b. Native vegetation on the site must be preserved to the greatest practical extent. Existing mature tree growth and natural landforms on the site must be preserved to the maximum extent possible. The applicant must provide a site plan to the Planning & Zoning Department showing existing significant vegetation to be removed and vegetation to be replanted to replace that lost or removed.
c. The Planning Commission may waive or modify the landscaping requirement where lesser requirements are desirable for adequate visibility for security purposes, for continued operation of existing bona fide agricultural or forest uses such as farms, nurseries, and tree farms, or where an antenna is placed on an existing structure. In certain locations where the visual impact of the tower would be minimal, such as remote agricultural or rural locations or developed heavy industrial areas, the landscaping requirement may be modified or waived by the Planning Commission.
8. Maintenance Impacts. Equipment at a transmission facility must be automated to the greatest extent possible to reduce traffic and congestion. Where the site abuts or has access to a collector street or arterial street, access for maintenance vehicles must be exclusively from the collector street or arterial street and not any local street.
9. Principal, Accessory and Joint Uses.
a. Accessory structures used in direct support of a telecommunications facility are allowed but may not be used for offices, vehicle storage, or other outdoor storage. Mobile or immobile equipment not used in direct support of a telecommunications facility may not be stored or parked on the site of the telecommunications facility.
b. Telecommunications facilities may be located on sites containing another principal use. Joint use of a site is prohibited when a proposed or existing principal use includes the storage, distribution, or sale of volatile, flammable, explosive, or hazardous materials such as propane, gasoline, natural gas, or dangerous chemicals.
10. Setbacks and Separation.
a. The following setbacks apply to all towers and antenna, provided, however, that the Planning Commission may reduce the setbacks when technologically required or visually preferable, and only if the placement will not endanger adjacent properties in the event that the tower fails.
i. Towers must be set back a distance equal to the height of the tower from any off-site residential structure.
ii. Towers, guys, and accessory facilities must satisfy the minimum zoning district setback requirements.
b. For antennae attached to the roof or a supporting structure on a rooftop, a 1:1 setback ratio (for example, a 10-foot-high antenna and structure requires a 10-foot setback from the edge of the roof) must be maintained unless an alternative placement is shown to reduce visual impact.
B. Additional Requirements for Towers
1. Site location and development must preserve the preexisting character of the surrounding buildings and land uses as much as possible. Towers must be integrated through location and design to blend in with existing characteristics of the site to the extent practical.
2. Towers may not be within one mile of another tower. However, the Planning Commission, as part of the application process, may waive this requirement when they determine the placement of another tower within one mile is technologically required or visually preferable.
3. Towers may not be sited where they will negatively affect historic properties, as designated by the Georgia or National Registry of Historic Places.
4. Placement of more than one tower on a lot may be permitted, provided all setback, design, and landscape requirements are met for each tower. Structures may be located as close to each other as technically feasible, as long as such placement will not lead to multiple failures in the event that one tower fails.
Read this code where it is posted (county website (glynncounty.org)) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.