The following site development standards apply to all newly constructed buildings used for office, commercial, industrial, institutional, and public purposes within the GCOD.
A. Transitional Buffers.
1. Applicability.
a. Transitional buffers required in this section must provide an effective visual screen between dissimilar uses or activities unless permitted as a single project per Sec. 6.2.3.E.3.
b. A transitional buffer is required along and inside the property line of a nonresidential property abutting a residential use or residentially zoned property.
c. Transitional buffers are required along and inside the property line at the perimeter of a planned development district that abuts single-family residential zoning or uses, in accordance with the requirements of this subsection, but no transitional buffers are
required between dissimilar uses within the planned development district.
2. Width of transitional buffer.
a. Where a commercial zoning district abuts property zoned for single-family residential, multi-family residential or agricultural use, the width must be at least 25 feet.
b. Where an industrial zoning district abuts property zoned for residential or agricultural use, the width must be at least 50 feet.
c. Public and institutional uses must comply with the standards in this section that apply to commercial zoning districts.
3. Transitional buffers that are at least 25 feet in width or greater must
meet at least two of the three following criteria:
a. Be planted with a staggered double row of evergreen trees at least six feet in height, or
b. A single row of deciduous shade trees at least two inches caliper DBH with a minimum height of 30 feet at maturity and two staggered rows of evergreen shrubs at least three feet in height, planted a maximum of four feet on center, or
c. Other arrangements which provide a similar visual screen, as approved by the Director.
4. Adjustments to buffer width.
a. If a 6 foot high solid wood fence or masonry wall is incorporated into the design of a transitional buffer, the width of the buffer may be reduced by no more than 10 feet. The fence or wall must be located on the inside of the vegetation required in Sec. 6.2.5.A.3., with the finished side facing the adjacent property.
b. Walls or fences required to screen loading and service areas, outdoor storage, and accessory equipment required in Sec. 6.2.5.B. may not be used to reduce the width of a transitional buffer required in Sec. 6.2.5.A.
B. Additional Landscape and Screening Standards.
1. Shrubs must be planted within ten feet of the foundation of the primary structure along each building facade at the rate of at least 20 shrubs per 100 lineal feet of building facade except for sides or rear of building used for loading or service areas.
Foundation plantings may be clustered to provide visual interest.
2. Along each street frontage there must be a landscape strip at least 10 feet in width except for perpendicular crossings for driveways and utilities.
a. The landscape strip must be planted with shade trees at least six feet tall and two inches caliper, DBH at time of planting, with a height of at least 35 feet tall at maturity.
b. Trees must be planted no less than 40 feet on center.
c. Shrubbery forming an intermittent hedge at least three feet in height and designed to
provide an adequate screen must also be provided within the landscape strip.
3. The Director has authority to approve alternative methods for landscaping and screening parking lots that include at least the same amount of landscape material or screening effect when viewed from the street.
4. In addition to general perimeter landscaping and required buffers, if Figure 6-1. Transitional Buffer Design a loading or service area is located within 50 feet of a side or rear lot line abutting a residential district or use or a public or institutional use, then the loading or service areas must be surrounded by either a masonry wall or opaque fence at least 6 feet in height and placed on the inside of the landscaped buffer required in Sec. 6.2.6.A.
5. Screening of storage and accessory equipment.
a. Waste receptacles, including dumpsters, garbage cans, or grease containers must be located in the rear or side yard and placed at least 20 feet from any street, public sidewalk, or property line that abuts a residential district or residential use. Such waste receptacles must be screened from view from all property lines and public areas of the site by a wall at least 6 feet in height constructed of masonry or solid wood with an opaque gate.
b. Rooftop mechanical equipment, including HVAC and utility equipment, must be screened from adjacent streets, sidewalks, residential districts or uses, or public and institutional uses. Screening must consist of parapet walls or an opaque enclosure around the equipment. Enclosures must be constructed of a material compatible with those used on the primary facade of the
principal structure.
c. Ground-mounted or wallmounted equipment such as HVAC equipment, transformers, and gangs of multiple utility meters must be screened from adjacent streets,
sidewalks, residential districts or uses, or public and institutional uses. Screening may consist of a solid masonry wall or wooden fence or other opaque enclosure around the equipment that is constructed of a material compatible with those used on the primary facade of the building. The height of the fence or wall must be sufficient to effectively screen the equipment from view.
d. Outdoor storage or sales displays are prohibited from front yards unless granted special use approval by the Board of Commissioners pursuant to the procedures of this UDC. Outdoor storage or sales
displays must be screened from view from public streets and adjacent property by a solid fence or wall at least 8 feet in height, except as follows:
i. Upon approval by the Director, the temporary sale of seasonal goods may be permitted on properties other than residentially zoned property for a period not to exceed 90 days, with up to a 30-day extension, to be approved no more than two times in a given calendar year. Such temporary sales are limited to sites that:
i. Provide adequate offstreet parking on approved surfaces;
ii. Provide safe and adequate vehicular access; and iii. Are not adjacent to residentially zoned property.
ii. Outdoor display and sale of goods may be permitted in designated parking areas provided that the
parking is not reduced below the minimum required in Sec. 8.1.
6. Cuts and fills of slopes must be terraced to blend into the natural terrain. Cut or fill slopes more than 10 feet in height must be landscaped with evergreen shrubbery planted at the rate of 10 shrubs per every 100 lineal feet.
C. Parking Lot Design.
1. Off-street parking is required as indicated in Sec. 8.1 of this UDC, except as provided in this subsection:
a. The Director may approve a reduction in the number of parking spaces required for a specific use where inter-parcel access is provided and a shared parking analysis demonstrates that adequate parking will be provided with the approved reduction.
b. The maximum number of parking spaces that may be constructed on impervious
surfaces may be no more than 125 percent of the minimum number of parking spaces required in Sec. 8.1.
2. In addition to the construction and design standards of Sec. 8.1.3, the following standards apply to all parking lots within the GCOD.
a. Each parking area with at least 20 spaces must include landscaped islands within the parking area equivalent to not less than 10 percent of the total paved area of the parking lot, not including pervious paving surfaces.
b. Landscaping in parking lots must contain at least one shade tree at least six feet in height and two inches caliper DBH at time of planting with a mature height of at least 35 feet for each 200 square feet of landscaping. Shade trees must be planted in a bed of ground cover, sod or low shrubbery.
c. Parking areas must be designed to facilitate safe and convenient use by pedestrians. Commercial and multi-family developments must provide designated pedestrian pathways or sidewalks at least 5 feet in width connecting parking aisles to the front entrance of the principal building.
d. All parking areas must be paved with asphalt, concrete or pervious materials as approved by the Director.
e. Off-street parking must be located to the side or rear of the principal building and may not be located between the principal building and the street.
3. Perimeter landscaping.
a. Where parking lots abut adjacent residentially zoned property, a transitional buffer is required as provided in Sec.
6.2.5.A.
b. Where parking lots abut public streets, a frontage landscape strip is required as provided in Sec. 8.1.3.
c. The following are considered appropriate tree species for perimeter and parking lot landscaping:
i. Nutall oak.
ii. Shumard oak.
iii. Willow oak.
iv. Gingko (Variety:
President, Autumn Gold, male gender).
v. Princeton elm.
vi. Chinese Elm (varieties Allee, Athena, Drake, Bosque).
vii. Bald Cypress (variety:
Shawnee Brave).
viii. Zelkova (variety Green Vase or Village Green).
ix. Northern red oak.
x. Autumn maple.
xi. Other native species as approved by the Director.
D. Outdoor lighting.
1. Streetlights.
a. Streetlights must be provided on all public streets.
b. The spacing of streetlights must be staggered, 300 feet oncenter, along both sides of the roadway.
c. All street lighting is subject to review and approval of the Hall County Public Works Department.
d. All outdoor lighting must be the semi-cutoff type.
2. Semi-cutoff luminaries must be used for all security lighting.
E. Inter-parcel access.
1. Inter-parcel access, joint driveways, cross access drives and access easements for nonresidential development that abuts other nonresidential development should be provided.
2. When provided, inter-parcel access must incorporate the following:
a. A continuous cross-access drive located in a cross-access easement to connect adjacent parcels along the thoroughfare.
b. A design speed of 15 mph and a two-way travel aisle with a minimum paved width of 22 feet (back of curb to back of curb). Paving, base and curb specifications must meet Hall County's standards for public streets.
c. Driveway aprons, stub-outs and other design features indicating that abutting properties may be connected to provide
cross access via a service drive.
d. A sidewalk at least 5 feet in width on one side of the crossaccess drive.
e. New commercial developments that abut residential property must provide a sidewalk at least five feet in width to connect the two uses.