The following design guidelines and standards apply to all newly constructed buildings used for multi-family residential, office, commercial, industrial, institutional, and public purposes.

A. General Architectural Requirements.

1. Principal building entrances must face public streets except for internal buildings not directly fronting a street.

2. Any nonresidential building located within 150 feet of a residential or agricultural use is limited to no more than 40 feet in height as defined in Sec. 2.1.

3. All buildings along U.S. 129 are limited to no more than 30 feet in height as defined in Sec. 2.1.

4. All buildings along State Route 365 are limited to no more than 50 feet in height as defined in Sec. 2.1.

B. Building Materials.

1. The use of a common palette of building materials must be maintained for all four sides of principal buildings to create a consistent architectural identity. For nonresidential or multi-family building facades greater than 100 feet in length, variation in building materials, texture, and depth may be employed to provide design variation.

2. Buildings that are located on outparcels and all accessory buildings must be constructed of materials

compatible with the principal building with which they are associated.

3. Building materials used for all four sides of new or reconstructed buildings are restricted to the following:

a. Brick.

b. Natural stone such as granite, limestone, marble or similar materials. Terra cotta or cast stone simulating natural stone is also acceptable. Painted stone is prohibited.

c. Split-face block/concrete masonry unit (CMU) is restricted to no more than 50 percent of the surface area of each side of a principal nonresidential building.

d. Split-face block/concrete masonry unit (CMU) is considered prohibited materials for any multi-family residential building.

e. Stucco is restricted to no more than 50 percent of the surface area of each side of a building.

f. Glass and glass block.

g. Architectural metal panels are restricted to no more than 50 percent of the surface area of each side of a building.

h. Precast or prestressed concrete may be used for industrial buildings.

i. Exposed concrete block or painted concrete block are considered prohibited materials for any exterior wall.

4. Restrictions on the use of metal building materials does not apply to entry doors or roll-up doors.

5. The amount of permitted material must be calculated using the gross square footage of wall area for each elevation of the building, including windows, doors or other openings.

C. Roof Materials.

1. Materials for pitched roofs are limited to architectural grade composition shingles, natural slate, natural terra cotta, natural wood shake, or factory finished metal with standing seams. Alternative materials not listed may be used upon approval from the Director.

2. Thermoplastic Polyolefin (TPO) may be used on flat roofs.

Meetings that refer to this section

Found 1: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:hall-county/zoning/6.2.6@2026-05-28-df96f496e0

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Hall County Zoning Ordinance, 6.2.6. Architectural Standards | Georgia Commons