Hawkinsville · Zoning Ordinance
Appendix A - UNIFIED LAND DEVELOPMENT REGULATIONS / Article V - LAND DEVELOPMENT ACTIVITIES / Division 5 - INSTALLATION OF STREETS AND UTILITIES
Sec. 5.5.2. Testing requirements.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
It is the responsibility of the developer to insure that all required tests are made and reported to the city. The cost of all testing and quality control shall be performed at the expense of the developer by qualified testing laboratories.
Type of Test to be Performed Minimum Number of Tests Testing Standards Sub-grade Compaction
Each 500 linear feet of roadway 95% Max Density ASTM-1557 Field Tests ASTM D-1556 F-2922 and D-2167 Base Compaction Each 500 linear feet of roadway 100% Max Density ASTM-1557 Field Tests ASTM D-1556 F-2922
and D-2167 Asphalt Density Each 1,000 linear feet of roadway 92% Laboratory Density Asphalt Thickness Each 500 linear feet of roadway Deficient in thickness not more than 1
/4" (Ord. of 5-10-96)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.