Manchester · Zoning Ordinance
Appendix B - DEVELOPMENT ORDINANCE / Chapter 4 - IMPROVEMENT STANDARDS
Section 4.36. Storm drainage detention structures on site.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The city may require on-site storm drainage and detention facilities for any subdivision, or commercial or industrial development project.
The rate of run-off from any development shall not exceed the rate that existed prior to the development. On-site detention facilities shall be constructed for a 100-year storm, and may include permanent retention basins, underground storage of storm water, roof system retention, parking lot design for controlled release of storm water, or other structures approved by the city engineer. Plans for storm water detention facilities shall be accompanied with storm water runoff calculations based on recognized formulas,
and shall conform to the requirements of generally accepted engineers practice.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.