501A-1 Procedures for Development. All manufactured home parks developed after adoption of this ordinance shall meet the following site plan requirements:
A. Site Plan Approval Required. All manufactured home park developments shall require site plan approval by the PZB in accordance with the procedures and requirements established herein. Site plans required herein for the placement
of three or more residential units shall contain the seal of a Georgia Registered Engineer or Surveyor. No building permits shall be issued for sites within any
development until final approval is granted subject to all park plan requirements.
B. Park Plan Submittal Requirements. All park plans shall be submitted to the
Building Inspector or Zoning Administrator accompanied by the required fee payment as established by the City of Manchester.
C. The name of the proposed park, and the name, address and telephone number of
the applicant.
D. Location map and legal description of the manufactured home park, north arrow
(designated magnetic or true).
E. Complete plans to scale of one inch equals not more than 100 feet and specifications of the proposed park showing: ! The area and dimensions of the tract of land; including topographic data at the
contour interval of not more than five feet or an interval appropriate for decision making on the tract; and including the location and type of soils on the tract.
Statement of accuracy signed by surveyor or engineer as applicable. ! The number, location and dimensions of all manufactured home lots.
! The location and width of streets; the location and size of drainage mechanisms proposed, including the size of each
application drainage area. ! The location of service buildings (laundry service, office, community building etc.) and other proposed structures. ! The location of water and sewer lines and riser pipes. ! Plans and specifications of the water supply and refuse and sewerage disposal
facilities. ! Plans and specifications of all buildings constructed or to be constructed with the park. ! The location of street lights, if applicable. ! The location of bulk refuse containers, perimeter walls, and park identification signs. ! A soil erosion and sedimentation plan meeting the requirements of the Soil
Erosion and Sedimentation Act. ! Certification from the appropriate authority on water and sewer acceptability.
F. Development Compliance. All required improvements, according to the site plan approved by the PZB, shall be installed
in each phase before the issuance of building permits.
501A-2 Regulations.
A. Soil and Ground Cover Requirements.
Exposed ground surfaces in all parts of every manufactured home park shall adhere to the following:
1. All streets shall be constructed so as to reduce dust, and in accordance with stipulations as shall be required by the City Building Inspector to ensure properly constructed streets.
2. All areas designated as yards shall be plated with grass or acceptable vegetative shrubs or flowers.
3. Any walkways to front or back entrances shall be covered with stone or other solid material capable of preventing soil erosion and eliminating objectionable dust.
B. Location and Frontage. A manufactured home park development shall be located
on property with a minimum frontage of 50 feet on a public street.
C. Site Drainage Requirements. The ground surface in all parts of every park site
shall be graded and equipped to drain all water in a safe, efficient manner.
D. Streets. All mobile manufactured home parks shall contain a street system
designated to provide convenient circulation within the park, and shall have one unobstructed access to a public street or highway. The following requirements shall apply to the development of the park
street system:
1. All internal streets shall meet the minimum requirements of the City of Manchester for all weather drives, and shall be a minimum of 20 feet in width.
2. All cul-de-sacs shall be constructed with a minimum 30-foot radius.
3. All park streets shall be maintained a state of good repair at all times by the owner(s) of the park.
4. Street design, base preparations, and surface construction materials shall meet the requirements of the county street and road standards.
Written approval of the street system by the City Building Inspector shall be required before the first building permit is issued.
E. Off-Street Parking Requirements. A minimum of two off-street parking spaces per lot shall be provided in all
manufactured home parks for the use of park occupants and guest.
F. Lot Area and Width. A manufactured home park development shall have a minimum area of ten contiguous acres with 30 percent for streets and other improvements. Individual unit spaces shall consist of 4,000 s.f. per unit.
Individual unit spaces shall comply with per unit minimum for Multi-Family
Districts as stated in Section 504
G. Setbacks Required:
1. No manufactured home or accessory building or structure shall be located closer than 30 feet to any
park perimeter property boundary.
2. Each manufactured home shall be setback from any other manufactured home by at least 20 feet.
3. There shall be a minimum distance of 20 feet between any individual manufactured home and an adjoining street, common parking areas, or other common areas.
H. Perimeter Buffer Required. An Undisturbed buffer consisting of trees and other landscaping material at least 30 feet in width shall be provided and maintained around the entire exterior perimeter of a manufactured home park.
Provided, however, any underground utilities may be placed within this buffer, but no closer than 20 feet from the perimeter of the park boundary. The property owner shall be responsible for the maintenance of the buffer, which shall be so maintained as to present a neat and orderly appearance and shall be kept free from refuse and debris.
I. Lighting. All manufactured home parks shall have lighting of height, spacing and intensity so that each home site's access and parking is appropriately illuminated.
Mercury vapor, or high or low pressure sodium lights shall be installed at not more than 200 feet intervals with a minimum height of 18 feet.
J. Water Supply.
1. Governmental Water System: All manufactured home parks shall connect to an existing public water system if such system is located
within 1,000 feet of the proposed park. The availability and adequacy of a public water supply shall be confirmed by the applicable agency having jurisdiction. If the public water supply is determined to be unavailable or inadequate for service, the Planning Commission may waive the requirement and allow an alternative water supply source.
2. Individual Water System: If individual wells are used, each well may be permitted to serve up to four service connections, provided that the construction method of each well shall meet the standards in accordance with the Georgia Annotated Code 12-5-138. The Water Well Standard Act of 1991, as amended.
K. Sewerage Disposal and Treatment: All manufactured home parks shall be required to exist to the existing city sewer system.
L. Electrical: All electric installations shall meet the requirements of the current
National Electric Code, as amended.
M. Refuse Collection Facilities: Each manufactured home park shall be provided with a sanitary method of solid waste
collection and disposal. Collection facilities shall be either in the form of bulk containers (dumpsters) of sufficient size and adequately distributed throughout
the park to meet the needs of the park residents, or at least one individually covered refuse containers having a capacity of 30 gallons or more for each occupied lot. Bulk containers shall either be
enclosed with a minimum of four feet high chain link fence and placed upon a concrete pad, with adequate draining to cities sewer, extending at least 18 inches around each container perimeter. Refuse
areas shall be maintained in a clean, sanitary manner so as not to attract, harbor or breed insects, rodents, or any manner of vermin or pest.
N. Service Buildings: Accessory structures and community service facilities are
hereby permitted for the convenience and well-being of park residents. Such structures shall conform to the Georgia State Building Codes adopted by the City of Manchester, as amended, and may
include, but are not limited to the following uses:
1. Park management offices, repair shops, and storage.
2. Community postal facilities.
3. Indoor community recreation areas.
4. Commercial uses supplying essential goods or services for park residents.
O. Miscellaneous Requirements:
1. Listings of Manufactured Home Required: Every person, or other entity owning or operating a manufactured home park, and each such entity engaged in the sale or rental of manufactured homes or lots upon which to place them, shall furnish the Tax Commissioner of Meriwether County on January 1 and July 1 of each year with a complete list of all manufactured homes parked or rented or otherwise located upon the property of the entity or in a park operated by an entity.
2. Restrictions on Occupancy: A manufactured home shall not be occupied for dwelling purposes unless it has met the installation requirements in this ordinance upon inspection by the Building Inspector of the City of Manchester.
P. Underpinning. Each Manufactured Home must be underpinned. Installation shall be in accordance with the manufacturers installation instructions. Acceptable materials include masonry, stone, metal, medium or heavy gauge vinyl or other
materials manufactured for the purpose of underpinning and approved by Building Inspector.
History
(Ord. of 1-9-2015)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.