Section 505. Setback requirements.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Residential Zoning District Front Footage (Ft.)

Minimum Front (Ft.)

Yard Side (Ft.) Size Rear (Ft.)

Minimum From Street Major Setback Centerline Other R-E Estate Residential 100' 40' 20%w 40' 60' 40' R-1 Low-Density 100' 40' 20%w 40' 60' 40' R-2 Medium-Density

Single 70 30' 20%w 30' 40' 30' Duplex R-3 Mediumto-HighDensity Single 60' 25' 10 25' 40' 30' Duplex 70 30' 10 30' 40' 30' Manufactured Housing 60' 25' 10 30' 40' 30' Apartments R-4 High-Density Single 30' 10 30' 30' 25' Duplex 30' 10 30' Apartments R-5 Manufactured Home Community 40' 10 20' 40' 30' Commercial* Zoning District Maximum Height Story Feet C-1 Local Commercial Businesses 4 35 Dwellings Same as R-4 C-2 General Commercial Businesses N/A N/A Dwellings Same as R-4 Industrial* *Refer to article 4, sections 439—441 for buffer and screening requirements.

Mountain Springs Zoning District Setback Requirements.

Subarea Minimum Front Parcel Frontage (Ft.)

Minimum Front Setback from Property Line (Ft.)

Minimum Side Yard Setback from Property Line (Ft.)

Minimum Rear Yard Setback from Property Line (Ft.)

Subarea 1 Mixed Use Village (NonResidential Uses) 15' 0' 0' 0' Subarea 1 Mixed Use Village (One Family Detached Homes) 30' 5' 5' 10' Subarea 1 Mixed Use Village (One Family Attached Homes and Townhomes) 15' 0' 0' between units and 10' between separate buildings 10' Subarea 1 Mixed Use Village (Zero Lot Line One Family Detached Homes) 30' 5' 0' on one side and 15' on the other side with at least 15' between adjacent principal dwelling units 10' Subarea 1 Mixed Use Village (Patio Dwelling One Family Detached or Attached Homes) 30' 5' 0' with minimum of 25% of lot as open space 0' with minimum of 25% of lot as open space Subarea 1 Mixed Use Village (Apartments/ Multifamily, Condominiums and rental units) 50' 5' 0' 10' Subarea 2 Rural Retreat (NonResidential Uses) 30' 10' 10' 20' Subarea 2 Rural Retreat (One Family Detached Homes) 35' 8' 8' 10' Subarea 2 Rural Retreat (One Family Attached Homes and Townhomes) 15 5' 0' between units and 10' between separate buildings 10' Subarea 3 Hamlet Residential (One Family Detached Homes) 30' 10' 8' 10' Subarea 3 Hamlet Residential (One Family Attached Homes and Townhomes) 15' 5' 0' between units and 10' between separate buildings 10' Subarea 3 Hamlet Residential (Zero Lot Line One Family Detached Homes) 30' 5' 0' on one side and 15' on the other side with at least 15' between adjacent principal dwelling units 10' Subarea 3 Hamlet Residential (Patio Dwelling One Family Detached or Attached Homes) 30' 5' 0' with minimum of 25% of lot as open space 0' with minimum of 25% of lot as open space Subarea 4 Residential Estate Home (Residential uses) 50' 25' 50' 50' Subarea 5 Mini-Farm (Residential uses) 50' 30' 75' 75' (Ord. of 1-9-2015; Ord. of 07-16-2023(1), 7-16-2023)