(a) Type 1, shopfront building. The shop-front building is a one-story commercial or retail building that fronts the public sidewalk.

(1) Height regulations.

a. Minimum floor height: 12 feet (one story).

b. Maximum floor height: 15 feet (one-story).

c. Maximum building height in TC.

d. District: 20 feet total with roof/parapet wall.

commercial or retail building that fronts Minimum Floor Height: 12 ft. (one story) Maximum Floor Height: 15 ft. (one-story) Maximum Building Height in TC 20 ft. total with roof/parapet wall.

Minimum: 20 ft.; Maximum: 40 ft.

Street Parking Requirements One space per 500 square feet of Roof Height: Max. 5 ft. parapet wall.

Patios permitted for outdoor dining.

Awning Depth: 4 ft. maximum.

(2) Building and lot standards.

a. Lot width.

1. Minimum: 20 feet;

2. Maximum: 40 feet.

b. Setbacks. See sections 40-29 through 40-31.

(3) Off-street parking requirements. One space per 500 square feet of retail.

(4) Additional requirements.

a. Roof height: maximum five feet parapet wall.

b. Patios permitted for outdoor dining.

c. Awning depth: four feet, maximum.

(b) Type 2, mixed-use building.

(1) Description. A mixed-use building has two or more floors, and allows the flexibility of having a vertical mixture of uses. The ground floor may be used for retail or office uses, while upper floors may be used for office, residential or lodging.

(2) Mixed-use standards.

a. Height regulations.

1. Minimum floor height.

(i) 12 feet, first floor;

(ii) Ten feet, second floor;

(iii) Ten feet, third floor;

(iv) 22 feet (two-story);

(v) 32 feet (three-story).

2. Maximum floor height.

(i) 15 feet, first floor;

(ii) Ten feet, second floor;

(iii) Ten feet, third floor;

(iv) 25 feet (two-story);

(iv) 35 feet (three-story);

(v) Maximum building height in TC district: 40 feet total with parapet wall.

Use building has two or more office uses, while upper floors may be

b. Building and lot standards.

1. Lot width: minimum 20 feet.

2. Setbacks: see sections 40-29 through 40-31.

c. Off-street parking requirements.

1. One space per dwelling unit.

2. One space per 500 square feet of retail/office.

d. Additional requirements.

1. Parapet wall: five feet maximum

2. Balcony depth: six feet maximum.

3. Patios permitted for outdoor dining.

4. Awning depth: six feet maximum.

Street Parking Requirements

(c) Type 3, live/work building.

(1) Description. A live/work building is a residential dwelling with a home office or retail component. The office or commercial component of the building is limited to the ground floor.

(2) Live/work standards.

a. Height regulations.

1. Minimum floor height.

(i) 12 feet, first floor;

A Live/Work building is a residential dwelling with a home office or retail (ii) Ten feet, second floor;

(iii) 22 feet (two-story).

2. Maximum floor height.

(i) 15 feet, first floor;

(ii) Ten feet, second floor;

(iii) 25 feet (two-story).

3. Maximum building height in TC district: 30 feet total with parapet wall.

b. Building and lot standards.

1. Lot width.

(i) Minimum: 20 feet;

(ii) Maximum: 40 feet.

2. Setbacks: see sections 40-29 through 40-31.

c. Off-street parking requirements. One space per dwelling unit. One space per 500 square feet of retail/office.

d. Additional requirement.

1. Parapet wall: five feet maximum.

2. Porch depth: six feet maximum; no porch on ground level.

3. Awning depth: same as porch depth.

(d) Type 4, civic building.

(1) Description. A building designed specifically for a civic purpose, such as government offices, schools, libraries, courthouses, or other similar purposes.

(2) Civic building standards.

a. Height regulations.

1. Minimum floor height.

(i) 12 feet, first floor;

(ii) Ten feet, second floor;

(iii) Ten feet, third floor;

(iv) 22 feet (two-story);

(v) 32 feet (three-story).

2. Maximum floor height.

(i) 15 feet, first floor;

(ii) Ten feet, second floor;

(iii) Ten feet, third floor;

(iv) 25 feet (two-story);

(v) 35 feet (three-story).

3. Maximum building height in TC district: 40 feet total with roof/ parapet wall.

b. Building and lot standards.

1. Lot width: minimum 30 feet; no maximum.

2. Setbacks: see sections 40-29 through 40-31.

c. Off-street parking requirements. One space per 300 square feet of gross floor area.

Maximum Building Height in TC District:

One space per 300 square feet of gross

d. Additional requirements.

1. Maximum five feet parapet wall.

2. Porch depth: ten feet maximum.

History

The history line the source prints at the end of the section.

(Code 1997, § 40-414; Ord. of 2-6-2012, § 1(40-414))