Sec. 22-621. Frontages and building elements.

About this text

  • As published by Municode, current through 2026-10-20
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Porches and stoops. Porches and stoops provide outdoor living space. Often, they provide protection from the sun, while still permitting breezes to infiltrate the body of the building. They provide architectural interest and delineate the building's entrance. This type is appropriate for residential building types with small setbacks. Typically, the porch or stoop is located in the build-to zone as close to the sidewalk as possible. It is elevated to ensure privacy within the building from those passing by.

Stairs may lead directly to the sidewalk or may be side-loaded.

Porches and Stoops (3 as 1)

(1) Depth:

a. Porch: eight-foot minimum;

b. Stoop four-foot minimum; eight-foot maximum.

(2) Length:

a. Porch: 25 percent to 100 percent of building front; ten-foot minimum.

b. Stoop: five-foot minimum; eight-foot maximum.

(3) Height, clear:

a. Eight-foot minimum.

b. Two-stories maximum.

(4) Porches and stoops may have multi-story verandas and/or balconies above.

(5) Finish level above grade: Two-foot minimum; five foot-maximum (no more than eight inches below the first interior finished floor level).

(6) Porches and stoops may occur forward of the build-to line, but shall not extend into the right-of-way. They may extend into the ROW upon the approval of an easement by the board of architectural review and zoning appeals.

(7) Stairs may extend forward of the build-to line into the right-of-way, or upon a utility easement if constructed of non-masonry, breakaway materials. Full sidewalk clearance shall be maintained.

(8) Porches and stoops are un-airconditioned. Screens on front porches are prohibited.

(b) Galleries, colonnades, arcades, and terraces. This frontage is associated with commercial uses, and is permitted to encroach upon the setback, or even into the right-of-way over the sidewalk. The space allows one to window-shop or dine in a shaded environment that also captures breezes. The frontage provides architectural interest and delineates the building's entrance. Upper stories may be enclosed, providing livable bonus space for occupants.

Galleries and Colonnades/Arcades (3 as 1)

(1) Depth:

a. Gallery: Eight-foot minimum from front wall of the building to the inside column face.

b. Colonnade/arcade: Ten-foot minimum from front wall of the building to the inside column face.

(2) Length: 75 percent to 100 percent of building front. On corners, may wrap around the side of the building facing the side street.

(3) Height, clear:

a. Ten-foot minimum.

b. Two-stories maximum. Additional stories may be permitted by the supervising planner.

Colonnades and arcades have two or more stories, with upper stories enclosed as habitable space.

(4) Finish level above grade: zero inches—six inches maximum.

(5) Galleries, colonnades, arcades, and terraces may occur forward of the build-to line, but may only extend into the right-of-way (to within two feet of curb) upon the approval of an easement by the board of architectural review and zoning appeals.

(6) In order to address changes in grade, and upon approval of the city planner, a terrace may be utilized in lieu of a gallery at a minimum depth: ten foot, minimum length: 75 percent to 100 percent of the building front (may wrap building on street side).

Terraces

(c) Balconies. A balcony is connected to a building's upper stories and is supported by either a cantilever or by columns on one side. This type is appropriate for residential and commercial buildings with small setbacks. Typically, the balcony is located forward of the build-to zone over the sidewalk. It allows occupants of the building to experience the activities of the street while also providing significant privacy from those passing by.

Balconies (2 as 1)

(1) Depth:

a. Second story: Five-foot minimum.

b. Upper story :Three-foot minimum.

(4) Length: 25 percent to 100 percent of building front; five-foot minimum.

(5) Height, clear:

a. First floor residential: Nine-foot minimum.

b. First floor nonresidential: Ten-foot minimum; eight-foot minimum with suspended signage.

Supporting brackets are exempt.

(6) Balconies shall occur forward of the build-to line and may encroach over the right-of-way to within two feet of the curb.

(7) Balconies shall be made of wood or metal and may have roofs, but are required to be open, un-airconditioned spaces. Balconies in the rear of the building may have screens.

(8) Ideally, balconies should be supported from below by visible brackets, scaled as if they are supporting the weight of the mass, or from above by suspension cables or chains.

(9) On corners, balconies may wrap around the side of the building facing the side street.

(d) Marquees, canopies, and awnings. A permanently roofed architectural projection whose sides are either vertical or horizontal and are supported entirely from an exterior wall of a building. This frontage is typically used for the display of signs. Horizontal marquees, canopies, and awnings provide shade from the sun, as well as enhanced weather protection for both the building and the passerby.

Canopies and Awnings (2 as 1)

(1) Depth: Five-foot minimum.

(2) Length: 25 percent to 100 percent of building front.

(3) Height, clear: eight-foot minimum (including suspended signage). The above requirements apply to the first floor only. There are no dimensional requirements for marquees, canopies, and awnings above the first floor.

(4) Sign copy on marquees, canopies, and awnings on second story windows is not permitted.

(5) Marquees, canopies, and awnings shall occur forward of the build-to line and may encroach over the right-of-way to within two feet of the curb.

(6) Marquees and canopies must be visually supported from below by brackets, or from above by suspension cables or chains.

(7) The top of each awning shall be at the same height as the top of each opening below.

(8) Awnings shall be made of fabric. Vinyl and high-gloss or plasticized fabrics are prohibited.

(9) Backlit awnings are prohibited.

(e) Drive-through facilities. Retail, restaurant, and service uses with a drive-through facility shall comply with the following standards:

(1) Building location and circulation. The dimensional and design standards established in this overlay code for building types and parking shall apply.

Building Location and Circulation (2 as 1) In no case shall a vehicular accessway/driveway or off-street parking area be permitted between the front facade of the building and the frontage street; or in the case of a corner lot, between the side facade of the building and the side street. Exception: buildings with a footprint in excess of 35,000 square feet that comprise a multi-building or campus development (see section 22- 620(k)).

(2) Access. Drive-through access may only occur from the front if there is no adjacent side street or alleyway.

Access (2 as 1)

(3) Configuration. Drive-throughs shall be located to the side or at the rear of the building and shall be designed so that pedestrian safety is ensured.

(4) Corner lot. Drive-throughs serving a building located on a corner lot shall be located to the rear or interior side. In no case shall the drive-through be located on the side of a building facing a street.

(5) Types. Both remote drive-through technology (in which objects are placed in a capsule and delivered to the drive-through via a tube) and attached drive-throughs are permitted.

(6) Roof. If covered, the roof over the drive-through shall be of a complementary architectural design as the design covering the primary portion of the structure. The roof on a multi-lane attached drive-through that is visible from the street may be designed as a porte cochere.

(7) Talk boxes. Talk boxes at drive-through facilities shall be screened by a sound barrier such as landscaping, a fence or a masonry wall.

History

The history line the source prints at the end of the section.

(Code 1991, § 22-503; Ord. of 3-10-2014, § 4; Ord. No. 11192014-1, § 4, 11-19-2014; Ord. No. 04112016-2, 4-11-2016; Ord. No. 12112017-1, § II, 12-11-2017)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:thomasville/zoning/22-621@2026-10-20-6891730bc9

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Thomasville Zoning Ordinance, Sec. 22-621. Frontages and building elements | Georgia Commons