Thomasville · Zoning Ordinance
Part II - CODE OF ORDINANCES / Chapter 22 - ZONING / Article XV - SPECIAL DISTRICTS / Division 2 - VICTORIA PLACE OVERLAY DISTRICT
Sec. 22-622. Architecture.
About this text
- As published by Municode, current through 2026-10-20
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Description.
(1) General. Within the overlay district, commercial, multifamily, and residential buildings should reflect a combination of vernacular and more formal architecture. This includes residential building types that are utilized for either residential or commercial purposes, and commercial building types that are used for a mix of nonresidential purposes. Essential characteristics include:
a. Raised or at-grade foundations.
b. A clearly discernable base (e.g., foundation/water table), middle, and top (e.g., roof) on each building.
c. The use of permanent and durable materials.
d. Buildings are typically simple combinations of one or more rectangular forms.
e. Simple, two to 2½ story massing, with predominantly gabled or hipped roof forms, and some parapeted roofs.
f. Both enclosed eaves with simplified classical detailing and exposed rafter ends.
g. Porches with simplified classical detailing.
h. Mixed architectural vocabulary, utilizing wood, stucco, and masonry.
(2) Residential buildings. Residential structures find precedent in the vernacular 11 /2-story cottages,
two-story houses with porches, and larger estates of downtown Thomasville.
(3) Multifamily buildings. Multifamily buildings find precedent in the mansion apartment houses and rowhouses of downtown Thomasville and are configured to resemble a large single-family house, or row of three or more attached townhouses.
(4) Commercial buildings. Commercial buildings are typically commercial in character, appearing as detached, single-use structures with parapeted or gabled, pedimented roof forms, and formal shopfronts or workshops.
(5) Mixed-use buildings. Mixed-use structures are modest in scale, and appear as detached, multistory commercial buildings.
(b) Massing.
(1) General.
a. Buildings shall incorporate variations in wall heights, facade articulations, and varied roof planes and pitches.
b. Wall planes shall be divided into visually distinct sections that provide visual order and create vertical proportions by the arrangement of windows and features such as columns, pilasters, canopies, and clearly-articulated entrances.
c. The main entrance to a building shall be clearly identifiable and shall be oriented to face a public street or space with direct sidewalk access. Entrances shall incorporate design features such as canopies, porticos, arcades, raised cornice parapets or peaked roof forms over the doorways, arches, and display windows.
d. Buildings in the overlay district shall be articulated and finished on all sides. Sides of commercial or mixed-use buildings that do not face (or will not likely face) a residential building or public street or space are exempt.
(2) Roofs.
a. Roofs are typically gabled, or hipped, with some flat.
b. Half stories are typically articulated utilizing gable ends and dormers.
c. Commercial and multifamily buildings shall have relatively steep slopes, ranging from eight in 12 to ten in 12. Larger commercial buildings may have slopes from four in 12 to eight in 12 or have flat roofs.
d. Porch roofs may have a lower pitch with a minimum slope of three in 12.
e. Roof penetrations and equipment (except chimneys) shall be screened by parapet, located on the rear slope, or otherwise configured to have as minimal visual impact as practicable from the public street or space.
f. Shed (monopitch) roofs shall only be attached to the principal building walls, with a minimum slope of two in 12.
g. Applied mansard roofs shall not be permitted.
h. Architectural (cupolas, towers, steeples, chimneys, etc.) and mechanical (heat and air, elevator enclosure, etc.) appurtenances may exceed the allowable building height as follows:
1. Roof area (combined): 25 percent maximum; height: 18 feet maximum.
2. Roof-wall connections.
(i) Eaves may utilize exposed rafter tails with minimal fascia depth or an enclosed cornice and entablature with simplified classical detailing. Box eaves (porkchops) shall be prohibited.
(ii) Roof overhangs shall have a minimum eight-inch overhang at eave and rake.
(3) Primary walls.
a. Primary walls may be clad in wood, cement fiber siding, brick, concrete masonry units with stucco (CBS), reinforced concrete with stucco, shingle, and/or vertical board and batten.
b. Siding may be mitered at building corners or clad with a minimum four-inch trim board.
Trim board is typically six inches.
c. Exposed wood shall be unpainted, painted, or stained.
d. Brick mortar joints shall be struck.
e. Stucco shall be smooth and sand finish only.
f. Two or more wall materials may be combined on one facade only with the lighter material above the more substantial material (e.g., wood above stucco or masonry, or stucco above masonry).
g. Decorative moldings, cornices, or an applied ornament of stone or cast concrete may be used to express the vertical division between the base, body, and the top.
h. Cantilevers shall be supported by visible brackets scaled as if they're supporting the weight of the mass above.
(4) Base.
a. Exposed foundation walls (below first floor) shall be: brick, painted brick, or stucco over block or concrete.
b. Primary walls, when set on a raised crawlspace foundation, should rest on a drip edge and water table or sill and fascia (wood or cementitious) over foundation piers.
c. Foundation piers shall be no less than 12-inches square. If the foundation is taller than four feet above grade, than the foundation piers shall be no less than 16-inches square.
d. Crawlspace openings and the undercroft of foundations, decks, and porches shall be framed in lattice, vertical pickets, and/or hogs pen pattern (wood or similar).
(c) Openings.
(1) Facade composition. Simple and regular rhythm of openings, often divided into equal bays of three, five, or seven.
(2) Windows and doors.
a. Windows may be double or single hung, or casement; with first story windows taller than upper story windows.
b. When utilized with wood cladding materials, windows and doors shall be framed with a minimum 3.5-inch wood or fiber cement trim or similar composite trim. When utilized with stucco or masonry cladding materials, windows and doors shall be framed with a minimum 2.5-inch brick mould.
c. All windows shall have a sill. The sill should not be integrated into a "picture frame" surround.
d. Windows shall be vertically- or square-proportioned and multi-paned with exterior true or simulated muntins.
e. Window panes may be in a one-over-one, two-over-two, six-over-six, or six-over-nine divided light pattern.
f. When windows are ganged together, a three-inch minimum mullion shall be between each individual window.
g. All glass shall be clear and non-reflective. If glass incorporates tinting, it should be transparent enough for those outside the building to see building occupants.
h. Shutters, when used, shall be sized equal to one-half the width and the same height as the window; and be operable.
i. Panels and windows on doors should be simple and rectilinear. Transom and side panel windows are allowed.
(3) Shopfronts (see section 22-628: definitions).
a. All regulations regarding windows and doors described above shall apply to a shopfront assembly.
b. The top of shopfront window sills shall be between one and three feet above the adjacent sidewalk.
c. Shopfront windows shall extend uninterrupted at least eight feet above the adjacent sidewalk.
d. Shopfront assemblies shall be made of painted or varnished wood, aluminum-clad wood, or painted metal.
e. In multi-story buildings, there shall be a horizontal band, articulated fascia, and/or entablature to separate the ground level shopfront from the upper floors. This band may be incorporated into the shopfront design.
f. Frontage treatments (e.g., porches, galleries, awnings, etc.) may be incorporated into shopfront designs.
g. Shopfront edges should integrate heavier piers or pilasters to visually carry the weight of the building above.
h. Lighting shall be mounted on the store front wall, preferably centered on the piers between windows/doors or centered above the windows/doors of the shopfront. Where projected shed roofs are used over entries the lighting may be mounted in the shed underside.
Lighting shall comply with section 22-625 (lighting).
(d) Frontage elements.
(1) Porches.
a. Bay spacing on porches shall remain vertically proportioned or square.
b. Columns should utilize architecturally correct capitals and bases. Columns shall be, width: six-inch minimum; shape: round or square (may be fluted, paneled, or tapered).
c. Porches shall be made predominantly of wood.
d. Railing spindles and pickets on porches shall not exceed four inches on center, or as required by the building code, whichever is less. Standard pipe rails are prohibited.
(2) Galleries, colonnades.
a. Bay spacing on galleries shall be vertically proportioned or square.
b. Columns should utilize architecturally correct capitals and bases. Columns shall be:
1. Width: six-inch minimum;
2. Shape: square or round.
(3) Balconies. Spindles and balusters on balconies shall not exceed four inches on center, or as required by the building code.
(4) Accessibility. ADA ramps may be incorporated into the architecture of the building, ideally along the side or rear facade. Such ramps may occur forward of the build-to line, but shall not extend into the right-of-way. They may encroach upon the side setback by five-foot maximum.
(e) Permitted materials.
(1) Cladding.
a. Siding in:
1. Wood (termite resistant, 50-year siding product).
2. Composition board.
3. Cement fiber siding (50-year siding product).
4. Vertical board and batten (using materials above).
b. Concrete masonry units with stucco (CBS).
c. Reinforced concrete with stucco.
d. Brick, with struck mortar joints.
e. Scored stucco imitation brick is prohibited. EIFS, Styrofoam, and other foam-based products are prohibited on building exteriors.
f. Vinyl and/or T-111 siding are not allowed.
(2) Foundations.
a. Brick.
b. Concrete.
c. Stucco.
(3) Roofing.
a. Narrow standing seam metal.
b. Painted 5-V or 8-V panel.
c. Rolled asphalt with ice and water shield.
d. Fiberglass, wood, or slate shingles.
(4) Windows.
a. Wood or clad wood.
b. Metal.
c. Steel.
d. Vinyl.
e. Fiberglass.
f. Extruded PVC.
(5) Doors.
a. Wood or clad wood.
b. Metal or steel.
c. Fiberglass.
(6) Trim.
a. Wood (termite resistant, 50-year product).
b. Composition board.
c. Fiber-cement board.
d. Molded millwork for built-up sections.
e. For soffits and porch ceilings:
1. Gypsum wall board (GWB).
2. Plaster.
3. Tongue and groove (T&G) wood.
4. Exposed rafters, or composite.
5. Vinyl panel systems are not permitted on porch ceilings.
6. If soffit is perforated, the pattern should be fragmented or as ambiguous as possible.
(7) Gutters.
a. Half round or ogee-profile metal.
b. PVC is not permitted.
(8) Downspouts.
a. Round or rectangular metal.
b. PVC is not permitted.
(9) Columns. Wood, fiberglass, composite, cast iron, concrete with smooth finish, brick, or stone.
(10) Railings.
a. Square balusters.
b. Turned spindles and ornamental shapes in wood or wrought iron.
(11) Chimneys.
a. Common brick.
b. Stucco.
History
(Code 1991, § 22-504; Ord. of 3-10-2014, § 5; Ord. No. 11192014-1, § 5, 11-19-2014)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.