Whitfield County · Zoning Ordinance
Appendix C - STORMWATER LOCAL DESIGN MANUAL
3.1.2. Pipes within the City of Dalton right-of-way.
About this text
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
All pipes located under roadways and within the public right-of-way of the City of Dalton, and that are accepted by the City of Dalton for long-term maintenance, shall be constructed of reinforced concrete pipe (RCP - Class 3) meeting Georgia Department of Transportation Standards. All pipes must have a minimum of 12 inches of cover from the exterior crown of the pipe, and in accordance with manufacturer's specifications. Pipes under pavement must have a minimum of 12 inches of cover from the exterior crown of the pipe to the bottom of the roadway base.
In situations where the City of Dalton or the county engineer have reason to suspect that a pipe system may have not been installed properly, the City of Dalton may require at their discretion, video inspections of pipe systems to be provided at the owner's expense prior to acceptance of the system.
3.1.3. Other pipe systems in Whitfield County (including City of Tunnel Hill and City of Varnell).
Pipe systems not within the public right-of-way of Whitfield County, City of Tunnel Hill and City of Varnell shall be constructed of RCP, HDPE, or CMP meeting Georgia Department of Transportation Standards and approved by Whitfield County Engineer. Minimum bedding standards for HDPE pipe and CMP shall be such that stone bedding (i.e. No. 57 stone) shall be placed to half of the pipe diameter for all depths greater than four feet and/or in accordance with manufacturer's specifications, whichever is greater.
All pipes must have a minimum of 12 inches of cover from the exterior crown of the pipe, and in accordance with manufacturer's specifications. Pipes under pavement must have a minimum of 12 inches of cover from the exterior crown of the pipe to the bottom of the roadway base. The minimum cover for pipes which run along individual lot property lines in residential developments shall be increased to three feet to account for the potential for damage due to residential fence construction.
All CMP shall be galvanized or aluminum coated (Type 2) steel pipe. Galvanized steel pipe must be galvanized with a minimum of four ounces of galvanization per square foot, and have three inch by one inch corrugation for pipe sizes of 36 inches in diameter and larger, and be 14 gauge or heavier construction. Aluminum coated (Type 2) must use steel sheet for corrugated steel pipe that meets AASHTO M 274M requirements. Those areas where a high ground water table exists and/or soil corrosivity and resistivity do not meet manufacturer's recommendations for a 50-year service life, only RCP may be utilized. The county engineer may, at its discretion, require soil tests to be provided at the owner's expense to determine corrosivity and resistivity of the soils as well as the presence and depth of the groundwater table. All soil tests performed by the owner must be performed in strict conformance with pipe manufacturer's specifications.
Maximum deflection of installed pipe systems shall be in accordance with manufacturer's specifications.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.