Skip to content
Georgia Commons
Menu

Brantley County · Code of Ordinances

Appendix A - SUBDIVISIONS / Article VI - DESIGN STANDARDS

Sec. 609. Benchmarks.

About this text

  • As published by Municode, current through 2025-04-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

At least two (2) permanent benchmarks shall be established within a subdivision or in each phase of a subdivision and located so that no lot is more than one thousand feet (1,000') from a benchmark. Permanent benchmarks shall be placed in the following locations:

a. In paved streets, offset from the center-line approximately halfway between the center-line and the pavement edge in a cast iron "water main valve" type box with an adjustable cover flush to the pavement (refer to Figure 6 in Appendix A).

b. In permanent open space areas or parks.

c. Other locations as approved by the County Engineer.

All benchmarks shall be identified on the final plat with location, elevations and reference to the source of original elevation with all pertinent data. If the final plat is approved and recorded prior to the completion of all improvements, a reproducible mylar copy of the final plat shall be submitted to the County with the benchmark data following the completion of all improvements which will maintain the same.

History

The history line the source prints at the end of the section.

(Ord. of 9-14-2010)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:brantley-county/code/609@2025-04-03-c72b9a6c97

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.