Brantley County · Código de ordenanzas
Appendix A - SUBDIVISIONS / Article VI - DESIGN STANDARDS
Sec. 609. Benchmarks.
Sobre este texto
- As published by Municode, current through 2025-04-03
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
At least two (2) permanent benchmarks shall be established within a subdivision or in each phase of a subdivision and located so that no lot is more than one thousand feet (1,000') from a benchmark. Permanent benchmarks shall be placed in the following locations:
a. In paved streets, offset from the center-line approximately halfway between the center-line and the pavement edge in a cast iron "water main valve" type box with an adjustable cover flush to the pavement (refer to Figure 6 in Appendix A).
b. In permanent open space areas or parks.
c. Other locations as approved by the County Engineer.
All benchmarks shall be identified on the final plat with location, elevations and reference to the source of original elevation with all pertinent data. If the final plat is approved and recorded prior to the completion of all improvements, a reproducible mylar copy of the final plat shall be submitted to the County with the benchmark data following the completion of all improvements which will maintain the same.
Historia
(Ord. of 9-14-2010)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.