Charlton County · Code of Ordinances
Part II - CODE OF ORDINANCES / Part A - GENERAL CODE OF ORDINANCES / Chapter 110 - BUILDINGS AND BUILDING REGULATIONS / Article II - PLUMBING / Division 2 - FLOW RESTRICTIONS ON FIXTURES
Sec. 110-53. Effective.
About this text
- As published by Municode, current through 2023-05-18
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The requirements of section 110-58 shall apply to any residential construction initiated after July 1,
b. Is a single flush water closet, including gravity, pressure assisted and electro-hydraulic tank types, that meets the following standards:
1. The average flush volume may not exceed 1.28 gallons;
2 The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and
3. The toilet must be listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification;
(2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;
(3) A urinal and associated flush valve that:
a. Uses no more than 0.5 gallons of water per flush;
b. Meets the performance, testing and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1;
c. For flushing urinals, meets all WaterSense™ Specifications for flushing urinals; and
d. Where nonwater urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Nonwater urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where nonwater urinals are installed they shall have a water distribution line roughed-in to the urinal location at a minimum height of 56 inches (1,422 millimeters) to allow for
the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where nonwater urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing;
(4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square inch
in accordance with American Society of Mechanical Engineers Standard A112.18.1/CSA B.125.1 and listed to the WaterSense™ High-Efficiency Lavatory Faucet Specification; and
(5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute.
History
(Code 1999, § 5-42)