(a) It is the intent of the board of commissioners to enforce the latest editions of the following State of Georgia Minimum Standard Codes, as adopted and amended by the State of Georgia from time to time. The following codes are hereby adopted for enforcement by reference as though they were copied fully herein:

(1) International Building Code;

a. The county further adopts Section 101 through Section 112 and Section 114 through Section 116 of Chapter 1 of such International Building Code for administration of such Code.

(2) International Mechanical Code;

a. The county further adopts Section 101 through Section 108 and Section 110 of Chapter 1 of such International Mechanical Code for administration of such Code.

(3) International Fuel Gas Code;

a. The county further adopts Section 101 through Section 108 and Section 110 of Chapter 1 of such International Fuel Gas Code for administration of such Code.

(4) International Plumbing Code;

a. The county further adopts Section 101 through Section 108 and Section 110 of Chapter 1 of such International Plumbing Code for administration of such Code.

b. Local Amendment to the Georgia State Minimum Standard Plumbing Code a/k/a the International Plumbing Code;

The Cherokee County Local Amendment to the Georgia State Minimum Standard Plumbing Code a/k/a the International Plumbing Code is as follows:

Chapter 2, Section 202 General Definitions.

Add in alphabetical order and revise, as applicable, the following definitions:

Kitchen faucet or kitchen faucet replacement aerator. A kitchen faucet or kitchen faucet replacement aerator that allows a flow of no more than 1.8 gallons of water per minute at a pressure of 60 pounds per square inch and conforms to the applicable requirements in ASME A112.18.1/CSA B125.1.

Lavatory faucet or lavatory faucet replacement aerator. A lavatory faucet or lavatory faucet replacement aerator that allows a flow of no more than 1.2 gallons per minute at a pressure of 60 pounds per square inch and is listed to the WaterSense High Efficiency Lavatory Faucet Specification.

Landscape Irrigation.

Flow sensor. An inline device in a landscape irrigation system that produces a repeatable signal proportional to flow rate.

Lawn or Landscape Irrigation system. An assembly of component parts that is permanently installed for the controlled distribution of water to irrigate landscapes such as ground cover, trees, shrubs, and other plants.

Lawn and Landscape Irrigation System refer to the same system.

Master shut-off valve. An automatic valve such as a gate valve, ball valve, or butterfly valve) installed as part of the landscape irrigation system capable of being automatically closed by the WaterSense controller. When this valve is closed water will not be supplied to the landscape irrigation system.

Pressure regulating device. A device designed to maintain pressure within the landscape irrigation system at the manufacturer's recommended operating pressure and that protects against sudden spikes or drops from the water source.

Rain sensor shut-off. An electric device that detects and measures rainfall amounts and overrides the cycle of a landscape irrigation system so as to turn off such system when a predetermined amount of rain has fallen.

WaterSense irrigation controller. Is a weather-based or soil moisture-based irrigation controller labeled under the U.S. Environmental Protection Agency's WaterSense program, which includes standalone controllers, add-on devices, and plug-in devices that use current weather data as a basis for scheduling irrigation.

WaterSense spray sprinkler bodies. A sprinkler body with integral pressure regulation, generating optimal water spray and coverage labeled under the U.S. Environmental Protection Agency's WaterSense program.

Shower head. A shower head that allows a flow of no more than the average of 2.0 gallons of water per minute at 80 pounds per square inch of pressure, is listed in the WaterSense Specification for Showerheads, and meets the US Department Definition of Energy definition of showerhead.

Chapter 6, Section 604.4 Maximum Flow and Water Consumption. Revise Section 604.4 to read as follows:

Consistent with the general approach taken in Georgia, these Maximum Flow and Water Consumption requirements and related definitions in Section 604.4 of the plumbing code shall apply to all plumbing systems, including those in one- and two-family dwellings. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 604.4.

Exceptions:

1. Blowout design water closets having a water consumption not greater than 3 gallons (13 L) per flushing cycle.

2. Vegetable sprays.

3. Clinical sinks having a water consumption not greater than 4� gallons (17 L) per flushing cycle.

4. Laundry tray sinks, and service sinks.

5. Emergency showers and eye wash stations.

TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING

FIXTURES AND FIXTURE FITTINGS

PLUMBING FIXTURE OR FIXTURE

FITTING

MAXIMUM FLOW RATE OR QUANTITYb

Lavatory faucet and replacement aerators, private WaterSense Labeled &

1.2 gpm at 60 psif Lavatory faucet, public (metering) 0.25 gallon per metering cycle Lavatory, public

(other than metering)

0.5 gpm at 60 psi Showerheada WaterSense Labeled &

2.0 gpm at 80 psif Kitchen faucet and replacement aerators

1.8 gpm at 60 psi f, g Urinal 0.5 gallon per flushing cyclef Water closet 1.28 gallons per flushing cycle c, d, e, f For SI: 1 gallon = 3.785 L, 1 gallon per minute = 3.785 L/m, 1 pound per square inch = 6.895 kPa.

a. A hand-held shower spray is a shower head. As point of clarification, multiple shower heads may be installed in a single shower enclosure so long as each shower head individually meets the maximum flow rate, the WaterSense requirements, and the US Department of Energy definition of showerhead. However, multiple shower heads are not recommended for water efficiency purposes.

b. Consumption tolerances shall be determined from referenced standards.

c. For flushometer valves and flushometer tanks, the average flush volume shall not exceed 1.28 gallons.

d. For single flush water closets, including gravity, pressure assisted and electro-hydraulic tank types, the average flush volume shall not exceed 1.28 gallons.

e. For dual flush water closets, the average flush volume of two reduced flushes and one full flush shall not exceed 1.28 gallons.

f. See 2014 GA Amendment to Section 301.1.2 'Waiver from requirements of high efficiency plumbing fixtures'.

g. Kitchen faucets are permitted to temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm (8.3 L/m) at 60 psi (414 kPa) and must revert to a maximum flow rate of 1.8 gpm (6.8 L/m) at 60 psi (414 kPa) upon valve closure.

604.4.1 Clothes Washers. Residential clothes washers shall be in accordance with the Energy Star program requirements.

604.4.2 Cooling Tower Water Efficiency.

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.