Early County · Code of Ordinances
Part II - CODE OF ORDINANCES / Chapter 34 - SUBDIVISIONS / Article IV - REQUIRED IMPROVEMENTS
Sec. 34-316. Storm drainage.
About this text
- As published by Municode, current through 2022-11-07
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) An adequate drainage system including necessary ditches, curbs, gutters, pipes, culverts, street drains, drip inlets, bridges, and other improvements shall be provided for the conducting of all surface water through the subdivision.
(b) Drains and cross drains shall be provided to accommodate all natural watercourses, as well as water flowing from the site and shall extend beyond the roadway shoulders sufficiently to protect the embankment slopes.
(c) Pipe sizes and slopes shall be determined by acceptable engineering calculations and shall provide for not less than a ten-year return frequency storm. In no case shall cross drains be less than 18 inches in diameter and side drains less than 15 inches in diameter.
History
(Res. of 6-1-1998(2), ch. II, art. IV, § 2.4-4)