Part II - CODE OF ORDINANCES / Chapter 8 - BUILDINGS AND BUILDING REGULATIONS / Article II - FLOW RATE RESTRICTIONS ON PLUMBING FIXTURES

Sec. 8-34. Residential buildings.

About this text

  • As published by Municode, current through 2025-02-18
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

The standards related to high efficiency plumbing fixtures shall include without limitation, the following:

(1) A water closet or toilet that:

a. Is a dual flush water closet that meets the following standards:

1. The average flush volume of two reduced flushes and one full flush may not exceed

1.28 gallons;

2. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as applicable:

(i) American Society of Mechanical Engineers Standard A112.19.2-2008; and (ii) American Society of Mechanical Engineers Standard A112.19.14-2006, SixLiter Water Closets Equipped with a Dual Flushing Device; and

3. Is listed to the WaterSenseTM Tank-Type High Efficiency Toilet Specification; or

b. Is a single flush water closet, including gravity, pressure assisted, and electro-hydraulic tank types, that meets the following standards:

1. The average flush volume may not exceed 1.28 gallons;

2. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and

3. The toilet must be listed to the WaterSenseTM Tank-Type High Efficiency Toilet Specification;

(2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;

(3) A urinal and associated flush valve that:

a. Uses no more than 0.5 gallons of water per flush;

b. Meets the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1;

c. For flushing urinals, meets all WaterSenseTM specifications for flushing urinals; and

d. Where non-water urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Non-water urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where non-water urinals are installed, they shall have a water distribution line roughed-in to the urinal location at a minimum height of 56 inches (1,422 mm) to allow for the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where non-water urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing;

(4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square inch in accordance with American Society of Mechanical Engineers Standard A112.18/CSA B.125.1 and listed to theWaterSenseTM High-Efficiency Lavatory Faucet Specification; and

(5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute.

History

The history line the source prints at the end of the section.

(Code 1994, § 14-59; Ord. of 2-5-1991, § b)