Part II - CODE OF ORDINANCES / Chapter 42 - FLOODS / Article II - FLOOD DAMAGE PREVENTION / Division 3 - PROVISIONS FOR FLOOD HAZARD REDUCTION
Sec. 42-99. New construction and/or substantial improvements.
About this text
- As published by Municode, current through 2026-01-16
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of section 42-92, "elevated buildings". All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated at or above one foot above the base flood elevation.