Section 5.2.8. Drainage System Construction.

About this text

  • As published by Municode, current through 2023-06-05
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

All pipe sizes shall be approved by the County Roads Superintendent to meet the drainage conditions of the watershed and area of the potential runoff, per current design standards and requirements. The minimum cross drain diameter shall be eighteen inches (18"). Minimum cover shall be twelve inches (12"). In all instances, depth requirements shall meet or exceed manufacturer's guidelines.

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.