Skip to content
Georgia Commons
Menu

Stephens County · Code of Ordinances

Part - CODE OF ORDINANCES / Chapter 38 - FLOODS / Article II - FLOOD DAMAGE PREVENTION / Division 3 - FLOOD HAZARD REDUCTION

Sec. 38-91. General standards.

About this text

  • As published by Municode, current through 2026-09-08
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

In all areas of special flood hazard, the following provisions are required:

(1) Anchoring.

a. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure.

b. All manufactured homes shall be anchored to prevent flotation, collapse or lateral movement by providing over-the-top or frame ties to ground anchors.

c. Specific requirements for manufactured homes shall be that:

1. Over-the-top ties be provided at each of the four corners of the manufactured home, with two additional ties per side at intermediate locations and manufactured homes less than 50 feet long requiring one additional tie per side;

2. Frame ties be provided at each corner of the home with five additional ties per side at intermediate points and manufactured homes less than 50 feet long requiring four additional

ties per side;

3. All components of the anchoring system be capable of carrying a force of 4,800 pounds; and

4. Any additions to the manufactured home be similarly anchored.

(2) Construction materials and methods.

a. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

b. All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage.

c. Any alteration, repair, reconstruction or improvements to a structure which is in compliance with the provisions of this article, shall meet the requirements of new construction.

d. For all new construction and substantial improvements, fully enclosed areas below the lowest floor that are subject to flooding shall be designed

to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer

or architect or must meet or exceed the standards set out in section 38- 92(3)a.

(3) Utilities.

a. Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to

prevent water from entering or accumulating within the components during conditions of flooding.

b. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system.

c. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of

floodwaters into the systems and discharges from the systems into floodwaters.

d. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding.

(4) Subdivision proposals.

a. All subdivision proposals shall be consistent with the need to minimize flood damage.

b. All subdivision proposals shall have public utilities and facilities such as sewer, gas, electric and water systems located and constructed to minimize flood damage.

c. All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards.

d. Base flood elevation data shall be provided for subdivision proposals (including manufactured home parks and subdivisions) and other proposed development which is greater than the lesser of 50 lots or five acres.

(5) Additional requirements for manufactured homes, manufactured home parks and subdivisions.

a. All manufactured home subdivisions and manufactured home parks located within zone A on the community's FIRM shall file an evacuation plan indicating alternate vehicular access and escape routes with appropriate disaster preparedness authorities and the field representative. Furthermore, such parks and subdivisions shall provide:

1. Adequate surface drainage and access for a hauler; and

2. In the instance of elevation on pilings:

i. Lots large enough to permit steps;

ii. Piling foundations placed in a stable solid no more than ten feet apart; and iii. Reinforcements for pilings more than six feet above the ground level.

b. All manufactured homes to be placed or substantially improved within zones A1—30, AH, and AE shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is at or above the base flood elevation and be securely anchored to an adequately anchored foundation system in accordance with the provisions of subsection (1) of this section.

(6) Floodways. Located within areas of special flood hazard established in section 38-38 are areas designated as floodways.

Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply:

a. Prohibit encroachments, including fill, new construction, substantial improvements and other developments unless certification by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in flood

levels during occurrence of the base flood discharge.

b. If subsection (6)a. of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this division.

c. Prohibit the placement of any manufactured homes, except in an existing manufactured home park or existing manufactured home subdivision.

(7) Encroachments. The cumulative effect of any proposed development shall not adversely affect the area of special flood hazard. This determination is to be made

in accordance with section 38-62(3).

(8) Alterations and repairs. Any alteration, repair, reconstruction, or improvements to a structure which is in compliance with the provisions of this article, shall meet the requirements of new construction.

History

The history line the source prints at the end of the section.

(Ord. No. 87-2, art. 5, § A, 8-4-1987)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:stephens-county/code/38-91@2026-09-08-a35cd53104

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.