Skip to content
Georgia Commons
Menu

Union County · Code of Ordinances

Part II - CODE OF ORDINANCES / Chapter 34 - FLOODS / Article IV - FLOOD HAZARD REDUCTION

Sec. 34-102. Specific standards.

About this text

  • As published by Municode, current through 2023-11-30
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

In all areas of special flood hazard within the county the following provisions shall be required:

(1) New construction and substantial improvements. Where base flood elevation data is available, new construction or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. If solid foundation perimeter walls are used to

elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards set forth in section 34-101(4).

(2) Nonresidential construction. New construction, or the substantial improvement of any structure located in A1-30, AE or AH zones, may be floodproofed in lieu of elevation.

The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one foot above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components shall have the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.

A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of this subsection, and the engineer or architect shall provide such certification to the floodplain administrator.

(3) Manufactured homes and recreational vehicles. Where base flood elevation data is available:

a. All manufactured homes placed or substantially improved on individual lots or parcels, in new or substantially improved manufactured home parks or subdivisions, in expansions to existing manufactured home parks or subdivisions or on a site in an existing manufactured home park or subdivision where a manufactured home has incurred substantial damage as the result of a flood must have the lowest floor, including basement, elevated no lower than one foot above the

base flood elevation.

b. Manufactured homes placed or substantially improved in an existing manufactured home park or subdivision may be elevated so that either the:

1. Lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation; or

2. Manufactured home chassis is elevated and supported by reinforced piers, or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above grade.

c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. (See subsection 34-101(6)).

d. All recreational vehicles placed on sites must:

1. Be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or

2. Meet all the requirements for new construction set forth in this chapter, including the anchoring and elevation requirements of subsections 34- 102(3)a.—c.

(4) Floodway. Located within areas of special flood hazard as established in section 34-37 are areas designated as floodways. A floodway may be an extremely hazardous area due to velocity floodwaters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply:

a. Encroachments are prohibited, including earthen fill, new construction, substantial improvements or other development within the regulatory floodway. Development may be permitted, however, provided, it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard

engineering practice that the encroachment shall not result in any increase in flood levels or floodway widths during a base flood discharge. A registered professional engineer must provide supporting technical data and certification of such analyses.

b. If the requirement set forth in subsection (4)a. of this section is satisfied, then any new construction or substantial improvement shall comply with all other applicable flood hazard reduction provisions of this article.

History

The history line the source prints at the end of the section.

(Ord. No. O-2000-002, art. 4, § B, 2-22-2000)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.