Skip to content
Georgia Commons
Menu

Union County · Code of Ordinances

Part II - CODE OF ORDINANCES / Chapter 34 - FLOODS / Article IV - FLOOD HAZARD REDUCTION

Sec. 34-103. Building standards for streams without established base flood elevations and/or floodways (A zones).

About this text

  • As published by Municode, current through 2023-11-30
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Located within the areas of special flood hazard established in section 34-37, where streams exist, but no base flood data has been provided (A zones), or where base flood data has been provided, but a floodway has not been delineated, the following provisions shall apply:

(1) When base flood elevation data or floodway data has not been provided in accordance with section 34-37, then the floodplain administrator shall obtain, review and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state or other source in order to administer the provisions of this article. If data is not available from such sources, the following provisions shall apply:

a. No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream, or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in more than one foot increase in flood levels during the occurrence of the base flood discharge.

b. In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area, including basement, elevated no less than three feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards set forth in subsection 34-101(4). Building sites which are filled and compacted, and which thereby create a building pad which is three feet above the highest adjacent grade, and which have the lowest floor of the lowest enclosed area, including basement, elevated no less than three feet above the highest adjacent grade are acceptable under the terms of this subsection. The floodplain administrator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.

History

The history line the source prints at the end of the section.

(Ord. No. O-2000-002, art. 4, § C, 2-22-2000; Amd. of 7-21-2005)