Located within areas of special flood hazard are areas designated as shallow flooding areas.

The following provisions shall apply in such areas:

(1) Residential buildings. All new construction and substantial improvements of residential buildings shall have the lowest

floor, including basement, elevated to the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no depth number is

specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade or at

least two feet above the most probable nearby base flood elevation. The greater of the two shall apply.

(2) Nonresidential buildings. All new construction and substantial improvements of residential buildings shall:

(a) Have the lowest floor, including basement, elevated to the depth number specified on the flood insurance rate

map, in feet, above the highest adjacent grade. If no depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest

adjacent grade or two feet above the most probable nearby base flood elevation. The greater of the two shall apply; or

(b) Together with attendant utility and sanitary facilities, the building shall be completely floodproofed to or above double the minimum elevation increment as defined in subsection (a) hereinabove, so that any space below that level is water tight

with walls substantially impermeable to the passage of water and with structural components having

the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set

forth above and as required in this article.

History

The history line the source prints at the end of the section.

(Res. of 1-7-02, § 2-13)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:whitfield-county/code/5-63@2026-05-11-2fa959ea9c

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.