Sec. 5-63. Standards for areas of shallow flooding.
Sobre este texto
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Located within areas of special flood hazard are areas designated as shallow flooding areas.
The following provisions shall apply in such areas:
(1) Residential buildings. All new construction and substantial improvements of residential buildings shall have the lowest
floor, including basement, elevated to the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no depth number is
specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade or at
least two feet above the most probable nearby base flood elevation. The greater of the two shall apply.
(2) Nonresidential buildings. All new construction and substantial improvements of residential buildings shall:
(a) Have the lowest floor, including basement, elevated to the depth number specified on the flood insurance rate
map, in feet, above the highest adjacent grade. If no depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest
adjacent grade or two feet above the most probable nearby base flood elevation. The greater of the two shall apply; or
(b) Together with attendant utility and sanitary facilities, the building shall be completely floodproofed to or above double the minimum elevation increment as defined in subsection (a) hereinabove, so that any space below that level is water tight
with walls substantially impermeable to the passage of water and with structural components having
the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set
forth above and as required in this article.