A. Demonstrate use of any GI/LID techniques as follows:

1. Vegetated Filter Strip—are uniformly graded and densely vegetated sections of land that provide "biofiltering" of stormwater runoff as it flows across the surface.

2. Bioretention Areas—are shallow stormwater basins or landscaped areas with well-draining soils, generally composed of sand, fines, and organic matter, and vegetation to capture and treat stormwater runoff.

3. Dry Wells—consist of shallow excavations, typically filled with stone, that are designed to intercept and temporarily store post-construction stormwater runoff until it infiltrates into the underlying and surrounding soils.

4. Permeable Paver System—is a pavement surface composed of structural units with void areas that are filled with pervious materials such as gravel, sand, or grass turf. The system is installed over a gravel base course that provides structural support and stores stormwater runoff that infiltrates through the system into underlying permeable soils.

5. A developer may request a different type of GI/LID practice from the GSMM upon the review and approval by the City.

B. Provide documentation of at least one of the following infeasibility criteria for cases where GI/LID applications cannot be applied in a feasible or sustainable manner:

1. The use of GI/LID application will impact threatened or endangered species habitat.

2. The use of GI/LID application will significantly damage a community, resource, such as a historical area, a park, a wildlife refuge, a nature trail, riparian zone, or a school facility.

3. The use of GI/LID would result in the violation of a Federal or State Law.

4. Steep Slopes < 6% for Dry Wells, Permeable Pavers, Vegetative Filter Strips; steep slopes > 20% for Bioretention Areas.

5. Inadequate Land Area < 2,500 ft2 for Dry Wells, < 5 acres for Bioretention Areas and Vegetative Filter Strips.

6. Depth to Water Table < 2 ft for Dry Wells, Bioretention Areas, Permeable Pavers, and < 1-2 ft for Vegetated Filter Strips.

7. Conflict with subsurface utilities.