Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 3 - DEVELOPMENT AND PERMITTING / Chapter 300 - SUBDIVISION AND DEVELOPMENT STANDARDS AND PROCEDURES / Article 4 - CONSTRUCTION PLANS AND INSPECTIONS

Section 300-38. Storm drainage profile drawing.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

When required, storm drainage profile drawings shall include:

(1) All information required under Subsection 300-24(b) (unless included elsewhere in the plans);

(2) Storm drainage profiles must be prepared to a scale no smaller than one inch = 100 feet horizontal × one inch = ten feet vertical;

(3) Each profile should be labeled consistent with the labeling scheme used on the drainage plan view;

(4) No main line storm pipe shall be less than 15 inches diameter; (roof laterals and landscape drainage are exempted from this requirement);

(5) No pipe shall have a slope greater than 12 percent;

(6) If a drop in a structure is greater than five feet, a reinforced base shall be provided for that structure;

(7) The 25-year hydraulic grade line shall be shown for all storm pipes. The 100-year HGL shall be shown for all pipes within road rights-of-way;

(8) No corrugated metal pipe shall be used in any road right-of-way;

(9) All utility crossings shall be shown on storm profiles;

(10) All structures shall be labeled as to type and function using standard county or GDOT call outs;

(11) No outfall pipe shall have a slope greater than one percent. Maximum allowable velocity for storm sewer exit pipe is ten feet per second when flowing full or half-full based on Manning's Formula. Energy dissipater is required for exit velocity in excess of five feet per second;

(12) Rip-rap and/or concrete aprons other acceptable aprons shall be shown for all outfalls;

(13) A pipe chart representing all sizing and capacity calculations, including but not limited to, pipe size, capacity, drainage area, velocity, and pipe material, shall be included;

(14) The profile must show the existing and proposed elevations along the length of the drainage system;

(15) Open channel design must show the grade of the flow line of the channel and include a typical ditch section that provides a non-erodible velocity at design flows. Channel slopes less than one percent may be grassed; for channel shapes greater than one but less than three percent the designer must demonstrate calculated velocity at or less than five feet per second including a channel lining for design to accommodate the design philosophy; channel slopes over three percent must be approved by the City;

(16) Channel lining (i.e., grass, concrete, etc.) must be specified along the profile;

(17) Pipe material and bedding shall be specified;

(18) Crown elevations must be matched at each junction structure or the upstream crown must be higher than the downstream crown; and

(19) Shall be compliant with the requirements of Chapter 340, Article 4, Post-Development Stormwater Management.

History

The history line the source prints at the end of the section.

(Ord. No. 743, 12-19-17; Ord. No. 757, 12-18-18; Ord. No. 805, 12-21-21)