Section 300-37. Grading plan.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

When required, grading plans shall include:

(1) All information required under Subsection 300-24(b) (unless included elsewhere in the plans);

(2) Topographic layout proposed grading of the development must be at two-foot (maximum) contour intervals based on mean sea level datum;

(3) Site grading plans superimposed over existing drainage structures. Drainage area that contributes to each existing structure shall be specified or shown;

(4) Location, and construction details, and design criteria of accessory structures (headwalls, drainage ditches, catch basins, junction boxes, drop inlets, retention areas, and retention outlet controls) shall be provided on plan and/or detail sheet;

(5) Maximum cross-slope on sidewalks is three percent, on other pavement, six percent;

(6) Northern and eastern coordinates shall be shown for all stormwater and sanitary sewer appurtenances;

(7) Bicycle and/or pedestrian-safe grates specified as appropriate for all drain inlets;

(8) Top and bottom elevations indicated for all walls, steps and ramps;

(9) Drainage at intersections indicated by flow arrows on plan;

(10) The 100-year floodplain limits and elevations, or note absence (specify latest floodplain map and panel);

(11) Structural detail and dimension of the detention pond including section through detention pond, dam or wall;

(12) All retaining walls over four feet in height must be certified by a structural engineer licensed in the State of Georgia;

(13) Ingress/egress easement from a public street to stormwater detention structure and maintenance easement to include the surface area ten feet outside the area inundated by the 100-year storm event. The ingress/egress easement shall be a minimum of 20 feet wide with a grade of 20 percent or less;

(14) Detail of outlet control structure;

(15) Show limits of actual grading (plus ten-foot grading buffer at the bottom of proposed slopes) outside of the root protection zone for all trees to remain;

(16) Establish easements for dedication of all stormwater drainage features directing concentrated flows across property lines as directed by the City;

(17) All development must satisfy the requirements of this UDO concerning potential flood areas;

(18) Show or indicate whether the site is part of and in compliance with a master/parent stormwater management plan;

(19) Water quality BMPs as recommended in the 2016 edition of the Georgia Stormwater Management Manual, Volumes 1, 2 and 3. For any project that requires a land disturbance permit the project shall consider water quality. The following BMPs may be used:

a. Wet ponds (extended detention for less than 20 acres)—ED-micro pool;

b. Extended dry detention ponds;

c. Wetland-constructed;

d. Infiltration trenches;

e. Dry swales;

f. Sand filter;

g. Bio-retention;

h. Vegetated filtration systems; and

i. Any other best management practice approved by the City Engineer.

History

The history line the source prints at the end of the section.

(Ord. No. 743, 12-19-17; Ord. No. 757, 12-18-18)