Cusseta-Chattahoochee County unified government · Zoning Ordinance
Appendix C - ROADWAY AND SUBDIVISION SPECIFICATIONS / 24 - Admixtures.
24.01. Air entraining admixtures. Materials for
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
air enhancement in Portland cement concrete mixtures shall meet the requirements of AASHTO:
M 154. Compression and flexure tests shall be made at seven and 28 days.
24.02 Chemical admixtures for concrete. Chemical admixtures for concrete shall meet the requirements for Type A, B, C, D, and F ASTM:
C494, unless otherwise specified. The length change requirements are waived. The admixtures shall contain not more than 0.8% chloride calculated as calcium chloride and the air content shall not exceed 4.0% when prepared in a standard batch without addition or air entraining agent.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.