Hall County · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT CODE / 9.4 - Street Construction Requirements
9.4.7. Installation of Utilities
About this text
- As published by Municode, current through 2026-05-28
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Underground utilities, including sewer services, all water lines and any cable
conduits under the pavement, shall be placed in the ground before the base material is in place.
B. All trenches shall be thoroughly compacted in six-inch layers with mechanical
compacting equipment.
C. All fire hydrants, utility poles, streetlights, transformer boxes and pedestals shall be set at a distance not less than six feet from the back of the curb.
D. The subgrade shall be scarified to a minimum depth of six inches and compacted to at least 98 percent maximum dry density immediately prior to the
placing of the base material.