Skip to content
Georgia Commons
Menu

Whitfield County · Zoning Ordinance

Appendix C - STORMWATER LOCAL DESIGN MANUAL

3.2.2. Dry underground detention ponds.

About this text

  • As published by Municode, current through 2026-05-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

No underground detention pond shall be constructed on residential development projects. Underground detention ponds may be considered on non-residential development projects after the designer has shown that construction of an aboveground detention pond is infeasible to the satisfaction of the county engineer. If allowed, all structures which are designed to store water shall be constructed of reinforced concrete or HDPE. Additionally, the structures should be designed such that vehicular traffic meeting an H-20 loading standard could traverse the area over the detention pond once backfilled or completed without resulting in structural failure of the pond. When designing the pond, the designer should design the structure such that routine maintenance can be accommodated without unreasonable demands being placed on future property owners.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:whitfield-county/zoning/3.2.2@2026-05-11-176bd3a6ea

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.