Sec. 3-222. Driveway culverts.

About this text

  • As published by Municode, current through 2022-10-28
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Where a wet weather drainage ditch exists between the proposed road and 20 feet into the lot, the design professional shall size the driveway culvert as if the driveway were at the lowest point on that lot. The construction plans shall show the minimum driveway pipe size required.

(b) Driveway culverts may be any of the types of pipe materials approved for longitudinal pipe installation.

(c) The inlet and outlet end of all driveway culverts shall have either flared-end sections or concrete headwalls that meet the standards of Georgia Department of Transportation 1120 or 1125.

History

The history line the source prints at the end of the section.

(Ord. of 5-17-2021(1))