Skip to content
Georgia Commons
Menu

Chamblee · Zoning Ordinance

Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 3 - DEVELOPMENT AND PERMITTING / Chapter 350 - INFRASTRUCTURE / Article 2 - DRAINAGE SYSTEM

Section 350-16. Culverts and pipe collection system guidelines.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Storm drainage profile drawing.

(1) No main line storm pipe shall be less than 15 inches diameter; (roof laterals and landscape drainage are exempted from this requirement);

(2) No pipe shall have a slope greater than 12 percent;

(3) If a drop in a structure is greater than five feet, a reinforced base shall be provided for that structure;

(4) No Corrugated Metal Pipe (CMP) shall be used in any publicly maintained road right-of-way;

(5) No outfall pipe shall have a slope greater than one percent. Maximum allowable velocity for storm sewer exit pipe is ten feet per second when flowing full or half-full, based on Manning's Formula. Energy dissipater is required for exit velocity in excess of five feet per second;

(6) Open channel design must show the grade of the flow line of the channel and include a typical ditch section that provides a non-erodible velocity at design flows. Channel slopes less than one percent may be grassed; for channel shapes greater than 12 but less than three percent the designer must demonstrate calculated velocity at or less than five feet per second including a channel lining for design to accommodate the design philosophy; channel slopes over three percent must be approved by the city;

(7) Crown elevations must be matched at each junction structure or the upstream crown must be higher than the downstream crown.

(b) Stormwater easements specifications are provided in subsection 340-39(a)(7).

History

The history line the source prints at the end of the section.

(Ord. No. 743, 12-19-17)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:chamblee/zoning/350-16@2026-11-14-ebe192864b

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Chamblee Zoning Ordinance, Section 350-16. Culverts and pipe collection system guidelines | Georgia Commons