(a) Storm drainage profile drawing.
(1) No main line storm pipe shall be less than 15 inches diameter; (roof laterals and landscape drainage are exempted from this requirement);
(2) No pipe shall have a slope greater than 12 percent;
(3) If a drop in a structure is greater than five feet, a reinforced base shall be provided for that structure;
(4) No Corrugated Metal Pipe (CMP) shall be used in any publicly maintained road right-of-way;
(5) No outfall pipe shall have a slope greater than one percent. Maximum allowable velocity for storm sewer exit pipe is ten feet per second when flowing full or half-full, based on Manning's Formula. Energy dissipater is required for exit velocity in excess of five feet per second;
(6) Open channel design must show the grade of the flow line of the channel and include a typical ditch section that provides a non-erodible velocity at design flows. Channel slopes less than one percent may be grassed; for channel shapes greater than 12 but less than three percent the designer must demonstrate calculated velocity at or less than five feet per second including a channel lining for design to accommodate the design philosophy; channel slopes over three percent must be approved by the city;
(7) Crown elevations must be matched at each junction structure or the upstream crown must be higher than the downstream crown.
(b) Stormwater easements specifications are provided in subsection 340-39(a)(7).
Historia
(Ord. No. 743, 12-19-17)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.