Areas of special flood hazard may include designated “AO” shallow flooding area. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. In these areas, the following provisions apply:

(a) All new construction and substantial improvements of residential and non-residential structures shall have the lowest floor, including basement, elevated to no lower than one foot above the flood depth number in feet specified on the FIRM, above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade. Flood openings hydrostatic flood forces shall be provided in accordance with standards of Section 10-19(e)(1).

(b) New construction and substantial improvements of non-residential structures may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to the specified FIRM flood level plus one foot above the highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components have the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice, and shall provide such certification to the City Manager, or his or her designee using the FEMA Floodproofing Certificate along with the design and operation/maintenance plan; and

(c) Drainage paths shall be provided to guide floodwater around and away from any proposed structure.