(a) Limited to one building. No more than one building shall be permitted to use a water service line.
(b) Piping. Only galvanized pipe shall be used for the installation of a service line.
(c) Depth. All service lines shall be installed at a depth of at least 40 inches below the surface of the ground.
(d) Stopcock and wastecock. Each service line shall contain a stopcock and wastecock where water may be turned on at the entrance of the water service pipe into the building.
(e) Shutoff valves. In all buildings other than dwellings, shutoff valves shall be installed which permit the water supply to all equipment in each separate room to be shut off without interfering with the water supply to any other room or portion of the building. All apartment complexes shall have a shutoff valve for each apartment.
(f) Compliance with plumbing code. All water connection installations shall comply with the city's plumbing code.