The requirements of this section apply to stand-alone towers and structures.
A. Height requirements.
1. For a single user, maximum height is seventy (70) feet;
2. For two (2) users, maximum height is one hundred (100) feet;
3. For three (3) users, maximum height is one hundred fifty (150) feet; and
4. Towers clustered at the same site shall be of similar height and design.
B. Towers shall be erected a minimum height necessary to provide parity with existing similar tower supported antenna, and shall be freestanding where the negative visual effect is less than would be created by use of a guyed tower.
C. Setbacks. Wireless support structures shall be set back from all property lines a distance that is at least equal to its engineered fall zone.
D. Security. Communication towers shall be enclosed by decay-resistant security fencing not less than six (6) feet in height and shall be equipped with an appropriate anti-climbing device that meets the requirements of division 6.5 - fences and walls.
E. Landscaping. Landscaping shall be used to effectively screen the view of the tower compound from adjacent public rights-of-way, public property, and residential property and shall be as follows:
1. A buffer area no less than six (6) feet wide shall commence at the base of the tower.
2. The buffer zone is to consist of materials of a variety and spacing which can be expected to grow to form a continuous hedge at least five (5) feet in height within two (2) years of planting.
3. Trees and shrubs in the vicinity of guy wires shall be of a kind that would not exceed twenty (20) feet in height or would not affect the stability of the guys, should they be uprooted, and shall not obscure visibility of the anchor from the transmission building or security facilities staff and maintenance.
4. Native vegetation on the site shall be preserved to the greatest practical extent. The applicant shall provide a site plan showing existing significant vegetation to be replanted to replace that lost.
5. In lieu of these standards, the city manager may allow use of an alternate detailed plan and specifications for landscape and screening, including plantings, fences, walls, and other features designed to screen and buffer towers and accessory uses. The plan shall accomplish the same degree of screening achieved by the provisions above, except as lesser requirements are desirable for adequate visibility for security purposes.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.