Ir al contenido
Georgia Commons
Menú

Banks County · Ordenanza de zonificación

Appendix A - ZONING / Chapter 5 - GENERAL BUILDING HEIGHTS AND AREAS

503.1.1. Basements.

Sobre este texto

  • As published by Municode, current through 2024-11-12
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

Basements need not be included in the total allowable area

provided they do not exceed the area permitted for a one-story building.

503.1.2 Special industrial occupations. Buildings and structures designed to house low-hazard industrial processes that require large areas and unusual heights to accommodate craneways or special machinery and equipment, including among others, rolling mills; structural metal fabrication shops and foundries; or the production and distribution of electric, gas or steam power, shall be exempt from the height and area limitations of Table 503.

TABLE 503

ALLOWABLE HEIGHT AND BUILDING AREAS

Height limitations shown as stories and feet above grade plane.

Area limitations as determined by the definition of "area, building", per floor.

TYPE OF CONSTRUCTION

TYPE I TYPE II TYPE III TYPE IV TYPE V

A B A B A B HT A B

HGT (ft) UL 160 65 55 65 55 65 50 40 GROUP Hgt(S) A-1 S A UL UL 5 UL 3 15,500 2 8,500 3 14,000 2 8,500 3 15,000 2 11,500 1 5,500 A-2 S A UL UL 11 UL 3 15,500 2 9,500 3 14,000 2 9,500 3 15,000 2 11,500 1 6,000 A-3 S A UL UL 11 UL 3 15,500 2 9,500 3 14,000 2 9,500 3 15,000 2 11,500 1 6,000 A-4 S A UL UL 11 UL 3 15,500 2 9,500 3 14,000 2 9,500 3 15,000 2 11,500 1 6,000 A-5 S A UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL B S A UL UL 11 UL 5 37,500 4 23,000 5 28,500 4 19,000 5 36,000 3 18,000 2 9,000 E S A UL UL 5 UL 3 26,500 2 14,500 3 23,500 2 14,500 3 25,500 1 18,500 1 9,500 F-1 S A UL UL 11 UL 4 25,000 2 15,500 3 19,000 2 12,000 4 33,500 2 14,000 1 8,500 F-2 S A UL UL 11 UL 5 37,500 3 23,000 4 28,500 3 18,000 5 50,500 3 21,000 2 13,000 H-1 S A 1 21,000 1 16,500 1 11,000 1 7,000 1 9,500 1 7,000 1 10,500 1 7,500 NP NP

TYPE OF CONSTRUCTION

TYPE I TYPE II TYPE III TYPE IV TYPE V

A B A B A B HT A B

HGT (ft) UL 160 65 55 65 55 65 50 40 GROUP Hgt(S) H-2 S A UL 21,000 3 16,500 2 11,000 1 7,000 2 9,500 1 7,000 2 10,500 1 7,500 1 3,000 H-3 S A UL UL 6 60,000 4 26,500 2 14,000 4 17,500 2 13,000 4 25,500 2 10,000 1 5,000 H-4 S A UL IL 7 UL 5 37,500 3 17,500 5 28,500 3 17,500 5 36,000 3 18,000 2 6,500 H-5 S A 3 UL 3 UL 3 37,500 3 23,000 3 28,500 3 19,000 3 36,000 3 18,000 2 9,000 I-1 S A UL UL 9 55,000 4 19,000 3 10,000 4 16,500 3 10,000 4 18,000 3 10,500 2 4,500 I-2 S A UL UL 4 UL 2 15,000 1 11,000 1 12,000 NP NP 1 12,000 1 9,500 NP NP I-3 S A UL UL 4 UL 2 15,000 1 10,000 2 10,500 1 7,500 2 12,000 2 7,500 1 5,000 I-4 S A UL UL 5 60,500 3 26,500 2 13,000 3 23,500 2 13,000 3 25,500 1 18,500 1 9,000 M S A UL UL 11 UL 4 21,500 4 12,500 4 18,500 4 12,500 4 20,500 3 14,000 1 9,000 R-1 S A UL UL 11 UL 4 24,000 4 16,000 4 24,000 4 16,000 4 20,500 3 12,000 2 7,000 R-2 a S A UL UL 11 UL 4 24,000 4 16,000 4 24,000 4 16,000 4 20,500 3 12,000 2 7,000 R-3 a S A UL UL 11 UL 4 UL 4 UL 4 UL 4 UL 4 UL 3 UL 3 UL

TYPE OF CONSTRUCTION

TYPE I TYPE II TYPE III TYPE IV TYPE V

A B A B A B HT A B

HGT (ft) UL 160 65 55 65 55 65 50 40 GROUP Hgt(S) R-4 S A UL UL 11 UL 4 24,000 4 16,000 4 24,000 4 16,000 4 20,500 3 12,000 2 7,000 S-1 S A UL UL 11 48,000 4 26,000 3 17,500 3 26,000 3 17,500 4 25,500 3 14,000 1 9,000 S-2 S A UL UL 11 79,000 5 39,000 4 26,000 4 39,000 4 26,000 5 38,500 4 21,000 2 13,500 U S A UL UL 5 35,500 4 19,000 2 8,500 3 14,000 2 8,500 4 18,000 2 9,000 1 5,500 For SI: 1 foot = 305 mm, 1 square foot = 0.0929 m2.

UL = Unlimited

a. As applicable in Section 101.2.

503.1.3 Buildings on same lot. Two or more buildings on the same lot shall be regulated as separate buildings or shall be considered as portions of one building if the height of each building and the aggregate area of buildings are within the limitations of Table 503 as modified by Sections 504 and 506. The provisions of this code applicable to the aggregate building shall be applicable to each building.

503.1.4 Type I construction. Buildings of Type I construction permitted to be of unlimited tabular heights and areas are not subject to the special requirements that allow unlimited area buildings in Section 507 or unlimited height in Sections 503.1.2 and 504.3 or increased height and areas for other types of construction.

503.2 Party walls. Any wall located on a property line between adjacent buildings which is used or adapted for joint service between the two buildings, shall be constructed as a fire wall in accordance with Section 705, without openings and shall create separate buildings.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:banks-county/zoning/503.1.1@2024-11-12-52af536ba7

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Banks County Zoning Ordinance, 503.1.1. Basements | Georgia Commons